Classification Malfunction Code Cause Resulting Operation Estimated Abnormal Parts Faulty Part Isolation DIPSW Control When
Main body: Communication error C-0001 Communication error between the printer control board (PRCB) and the PF drive board (PFDB) or LU drive board (LUDB). The main body stops immediately to turn OFF the power relay (RL1). • Printer control board (PRCB)
• PF drive board (PFDB)
• LU drive board (LUDB)
Main body: Communication error C-0002 Communication error between the printer control board (PRCB) and the conveyance drive board (COB). • Printer control board (PRCB)
• Conveyance drive board (COB)
Main body: Communication error C-0003 Communication error between the printer control board (PRCB) and the conveyance drive board (COB). • Printer control board (PRCB)
• Conveyance drive board (COB)
Main body: Paper feed motor abnormality C-0101 An error detection signal of M41 is detected continuously for a specified period of time while the paper feed motor (M41) is ON. • Printer control board (PRCB)
• Paper feed motor (M41)
LU: LU paper feed motor abnormality C-0102 An error detection signal of M1 is detected continuously for a specified period of time while the paper feed motor (M1) is ON. • LU drive board (LUDB)
• Paper feed motor (M1)
• Interlock switch /1 (MS1), /2 (MS2)
• Upper door sensor (PS100), front door sensor (PS115)
DIPSW18-3 LU paper feed is not available
PF: PF paper feed motor abnormality C-0103 An error detection signal of M1 is detected continuously for a specified period of time while the paper feed motor (M1) is ON. • PF drive board (PFDB)
• Paper feed motor (M1)
• Front door open/close switch (SW1)
• Front door open/close sensor (PS23)
DIPSW35-0 DIPSW35-1 DIPSW35-2
DIPSW35-3 DIPSW35-4 DIPSW35-5
PF paper feed is not available
Classification Malfunction Code Cause Resulting Operation Estimated Abnormal Parts Faulty Part Isolation DIPSW Control when
Main body: Paper feed tray abnormality C-0201 The upper limit sensor /1 (PS30) does not turn ON within a specified period of time after the paper lift motor /1 (M38) turns ON. • Printer control board (PRCB)
• Paper lift motor /1 (M38)
• Upper limit sensor /1 (PS30)
• Pick-up solenoid /1 (SD7)
DIPSW18-0 Paper feed in tray 1 is unavailable
Main body: Paper feed tray abnormality C-0202 The upper limit sensor /2 (PS36) does not turn ON within a specified period of time after the paper lift motor /2 (M39) turns ON. • Printer control board (PRCB)
• Paper lift motor /2 (M39)
• Upper limit sensor /2 (PS36)
• Pick-up solenoid /2 (SD8)
DIPSW18-1 Paper feed in tray 2 is unavailable
Main body: Paper feed tray abnormality C-0203 The upper limit sensor /3 (PS42) does not turn ON within a specified period of time after the paper lift motor /3 (M40) turns ON. • Printer control board (PRCB)
• Paper lift motor /3 (M40)
• Upper limit sensor /3 (PS42)
• Pick-up solenoid /3 (SD9)
DIPSW18-2 Paper feed in tray 3 is unavailable
LU: LU lift motor abnormality C-0204 A lock signal of M100 is detected while the paper lift motor (M100) is ON. • LU drive board (LUDB)
• Upper limit sensor (PS109)
• Paper lift motor (M100)
DIPSW18-3 LU paper feed is not available
LU: LU lift motor abnormality C-0205 A lock signal of M100 is detected while the paper lift motor (M100) is ON. • LU drive board (LUDB)
• Paper lift motor (M100)
• Upper limit sensor (PS109)
PF: Paper lift motor abnormality C-0208 The upper limit sensor /1 (PS1) does not turn ON within a specified period of time after the paper lift motor /1 (M2) turns ON. • PF drive board (PFDB)
• Paper lift motor /1 (M2)
• Upper limit sensor /1 (PS1)
DIPSW21-4 Paper feed in PF upper tray is unavailable
PF: Paper lift motor abnormality C-0209 Power supply line fuse for the paper lift motor /1 (M2) blows out. • PF drive board (PFDB)
• Paper lift motor /1 (M2)
DIPSW21-4 Paper feed in PF upper tray is unavailable
PF: Paper lift motor abnormality C-0211 The upper limit sensor /2 (PS9) does not turn ON within a specified period of time after the paper lift motor /2 (M3) turns ON. • PF drive board (PFDB)
• Paper lift motor /2 (M3)
• Upper limit sensor /2 (PS9)
DIPSW21-5 Paper feed in PF lower tray is unavailable
PF: Paper lift motor abnormality C-0212 Power supply line fuse for the paper lift motor /2 (M3) blows out. • PF drive board (PFDB)
• Paper lift motor /2 (M3)
DIPSW21-5 Paper feed in PF lower tray is unavailable
Main body: Paper exit abnormality C-0213 The paper exit pressure home sensor (PS10) does not turn ON within a specified period of time after it turns OFF. • AC drive board (ACDB)
• Printer control board (PRCB)
• Paper exit motor (M54)
• Paper exit pressure sensor (PS10)
Main body: Fan abnormality C-0301* An error detection signal of FM47 is detected continuously for a specified period of time while the main body fan (FM47) is ON. • Printer control board (PRCB)
• Main body fan (FM47)
Main body: Fan abnormality C-0302* An error detection signal of any of FM26 or FM28 is detected continuously for a specified period of time while the tucking fan /1 (FM26) and /3 (FM28) are ON. • Printer control board (PRCB)
• Tucking fan /1 (FM26)
• Tucking fan /3 (FM28)
Classification Malfunction Code Cause Resulting Operation Estimated Abnormal Parts Faulty Part Isolation DIPSW Control when
Main body: Fan abnormality C-0303 An error detection signal of FM66 is detected continuously for a specified period of time while ADU cooling fan /1 (FM66) is ON. • Conveyance drive board (CDB)
• ADU cooling fan /1 (FM66)
Main body: Fan abnormality C-0304* An error detection signal of any of FM61, FM62 or FM63 is detected continuously for a specified period of time while the paper exit cooling fans /1 (FM61), /2 (FM62) and /3 (FM63) are ON. • Printer control board (PRCB)
• Paper exit fan /1 (FM61)
• Paper exit fan /2 (FM62)
• Paper exit fan /3 (FM63)
Main body: Fan abnormality C-0305* An error detection signal of FM36 is detected continuously for a specified period of time while the deodorization fan (FM36) is ON. • Printer control board (PRCB)
• Deodorization fan (FM36)
LU: LU fan abnormality C-0306 An error detection signal of FM1 is detected continuously for a specified period of time while the paper feed assist fan /Fr (FM1) is ON. • LU drive board (LUDB)
• Paper feed assist fan /Fr (FM1)
LU: LU fan abnormality C-0307 An error detection signal of FM2 is detected continuously for a specified period of time while the paper feed assist fan /Rr (FM2) is ON. • LU drive board (LUDB)
• Paper feed assist fan /Rr (FM2)
PF: PF fan abnormality C-0308 An error detection signal of FM1 is detected continuously for a specified period of time while the paper feed assist fan /Fr11 (FM1) is ON. • PF drive board (PFDB)
• Paper feed assist fan /Fr11 (FM1)
PF: PF fan abnormality C-0309 An error detection signal of FM3 is detected continuously for a specified period of time while the paper feed assist fan /Fr12 (FM3) is ON. • PF drive board (PFDB)
• Paper feed assist fan /Fr12 (FM3)
PF: PF fan abnormality C-0310 An error detection signal of FM2 is detected continuously for a specified period of time while the paper feed assist fan /Rr11 (FM2) is ON. • PF drive board (PFDB)
• Paper feed assist fan /Rr11 (FM2)
PF: PF fan abnormality C-0311 An error detection signal of FM4 is detected continuously for a specified period of time while the paper feed assist fan /Rr12 (FM4) is ON. • PF drive board (PFDB)
• Paper feed assist fan /Rr12 (FM4)
PF: PF fan abnormality C-0312 An error detection signal of FM5 is detected continuously for a specified period of time while the paper feed assist fan /Fr21 (FM5) is ON. • PF drive board (PFDB)
• Paper feed assist fan /Fr21 (FM5)
PF: PF fan abnormality C-0313 An error detection signal of FM7 is detected continuously for a specified period of time while the paper feed assist fan /Fr22 (FM7) is ON. • PF drive board (PFDB)
• Paper feed assist fan /Fr22 (FM7)
Classification Malfunction Code Cause Resulting Operation Estimated Abnormal Parts Faulty Part Isolation DIPSW Control when
PF: PF fan abnormality C-0314 An error detection signal of FM6 is detected continuously for a specified period of time while the paper feed assist fan /Rr21 (FM6) is ON. • PF drive board (PFDB)
• Paper feed assist fan /Rr21 (FM6)
PF: PF fan abnormality C-0315 An error detection signal of FM8 is detected continuously for a specified period of time while the paper feed assist fan /Rr22 (FM8) is ON. • PF drive board (PFDB)
• Paper feed assist fan /Rr22 (FM8)
PF: PF fan abnormality C-0316 An error detection signal of any of FM11 or FM12 is detected continuously for a specified period of time while the dehumidifier fans /1 (FM11) and /2 (FM12) are ON. • PF drive board (PFDB)
• Dehumidifier fan /1 (FM11)
• Dehumidifier fan /2 (FM12)
PF: PF fan abnormality C-0317 An error detection signal of any of FM13 or FM14 is detected continuously for a specified period of time while the dehumidifier fans /3 (FM13) and /4 (FM14) are ON. • PF drive board (PFDB)
• Dehumidifier fan /3 (FM13)
• Dehumidifier fan /4 (FM14)
PF: PF fan abnormality C-0318 An error detection signal of any of FM10 or FM9 is detected continuously for a specified period of time while the ventilation fan /1 (FM10) and /2 (FM9) are ON. • PF drive board (PFDB)
• Ventilation fan /1 (FM10)
• Ventilation fan /2 (FM9)
LU: LU fan abnormality C-0320 An error detection signal of FM3 is detected continuously for a specified period of time while the dehumidifier fan /1 (FM3) is ON. • LU drive board (LUDB)
• Dehumidifier fan /1 (FM3)
LU: LU fan abnormality C-0321 An error detection signal of FM4 is detected continuously for a specified period of time while the dehumidifier fan /2 (FM4) is ON. • LU drive board (LUDB)
• Dehumidifier fan /2 (FM4)
Main body: Fan abnormality C-0322 An error detection signal of FM67 is detected continuously for a specified period of time while ADU cooling fan /2 (FM67) is ON. • Conveyance drive board (CDB)
• ADU cooling fan /2 (FM67)
Main body: Fan abnormality C-0323* An error detection signal of FM62 is detected continuously for a specified period of time while the paper exit fan /2 (FM62) is ON. The main body stops immediately to turn OFF the power relay (RL1). • Paper exit fan /2 (FM62)
• Printer control board (PRCB)
Main body: Fan abnormality C-0324* An error detection signal of FM63 is detected continuously for a specified period of time while the paper exit fan /3 (FM63) is ON. • Paper exit fan /3 (FM63)
• Printer control board (PRCB)
LU: LU power source abnormality C-0401 24VDC is not supplied to LU. The main body stops immediately to turn OFF the LU. • LU drive board (LUDB)
• DC power supply /2 (DCPS/2)
LU: LU power source abnormality C-0402 12VDC is not supplied to LU. The main body stops immediately to turn OFF the power relay (RL1). • LU drive board (LUDB)
• DC power supply /1 (DCPS1)
Classification Malfunction Code Cause Resulting Operation Estimated Abnormal Parts Faulty Part Isolation DIPSW Control when
PF: PF power source abnormality C-0403 24VDC is not supplied to PF. • PF drive board (PFDB)
• DC power supply /2 (DCPS2)
PF: PF power source abnormality C-0404 24VDC is not supplied to PF. • PF drive board (PFDB)
• DC power supply /2 (DCPS2)
PF: PF power source abnormality C-0405 12VDC is not supplied to PF. • PF drive board (PFDB)
• DC power supply /1 (DCPS1)
PF: PF power source abnormality C-0406 24VDC is not supplied to PF. • PF drive board (PFDB)
• DC power supply /2 (DCPS2)
PF: PF Tray 1 Heater high temperature hardware detection abnormality C-0407 24V power source abnormal signal is detected. • PF drive board (PFDB)
• Temperature sensor /3 (TEMS/3)
• AC drive board (ACDB) in PF
PF: PF Tray 2 Heater high temperature hardware detection abnormality C-0408 24V power source abnormal signal is detected. • PF drive board (PFDB)
• Temperature sensor /4 (TEMS/4)
• AC drive board (ACDB) in PF
PF: PF fan heater abnormality C-0409 Fan heater /Up (DH3) high temperature abnormality.
The temperature sensor /3 (TEMS/3) detects the prescribed or higher value continuously for a specified period of time.
• PF drive board (PFDB)
• AC drive board in PF (ACDB)
• Fan heater /Up (DH3)
• Temperature sensor /3 (TEMS/3)
• Dehumidifier fans /1 (FM11) and /2 (FM12)
PF: PF fan heater abnormality C-0410 Fan heater /Lw (DH4) high temperature abnormality.
The temperature sensor /4 (TEMS/4) detects the prescribed or higher value continuously for a specified period of time.
• PF drive board (PFDB)
• AC drive board in PF (ACDB)
• Fan heater /Lw (DH4)
• Temperature sensor /4 (TEMS/4)
• Dehumidifier fans /3 (FM13) and /4 (FM14)
PF: PF fan heater abnormality C-0411 Fan heater /Up (DH3) low temperature abnormality.
The temperature sensor /3 (TEMS/3) detects the prescribed or lower value continuously for a specified period of time.
• PF drive board (PFDB)
• AC drive board in PF (ACDB)
• Fan heater /Up (DH3)
• Temperature sensor /3 (TEMS/3)
PF: PF fan heater abnormality C-0412 Fan heater /Lw (DH4) low temperature abnormality.
The temperature sensor /4 (TEMS/4) detects the prescribed or lower value continuously for a specified period of time.
• PF drive board (PFDB)
• AC drive board in PF (ACDB)
• Fan heater /Lw (DH4)
• Temperature sensor /4 (TEMS/4)
PF: PF fan heater abnormality C-0413 Fan heater /Up (DH3) temperature rise abnormality.
The temperature detected by the temperature sensor /3 (TEMS/3) has not risen to a prescribed level within a specified period of time.
• PF drive board (PFDB)
• AC drive board in PF (ACDB)
• Fan heater /Up (DH3)
• Temperature sensor /3 (TEMS/3)
PF: PF fan heater abnormality C-0414 Fan heater /Lw (DH4) temperature rise abnormality.
The temperature detected by the temperature sensor /4 (TEMS/4) has not risen to a prescribed level within a specified period of time.
• PF drive board (PFDB)
• AC drive board in PF (ACDB)
• Fan heater /Lw (DH4)
• Temperature sensor /4 (TEMS/4)
LU: LU temperature sensor abnormality C-0415 The temperature sensor /2 (TEMS2) detects an error detection signal continuously for a specified period of time. (Hardware detection) • LU drive board (LUDB)
• Dehumidification heater /3 (DH2)
• Temperature sensor /2 (TEMS2)
• AC Drive Assy
• Main body AC drive board (ACDB)
LU: LU dehumidifier heater abnormality C-0416 Dehumidifier heater /3 (DH2) high temperature abnormality. The temperature sensor /2 (TEMS2) detects the prescribed or higher value continuously for a specified period of time. (Software detection) • LU drive board (LUDB)
• Dehumidification heater /3 (DH2)
• Temperature sensor /2 (TEMS2)
• AC drive assy
• Main body AC drive board (ACDB)
LU: LU dehumidifier heater abnormality C-0417 Dehumidifier heater /3 (DH2) low temperature abnormality. The temperature sensor /2 (TEMS2) detects the prescribed or lower value continuously for a specified period of time. • LU drive board (LUDB)
• AC Drive Assy
• Main body AC drive board (ACDB)
• Dehumidification heater /3 (DH2)
• Temperature sensor /2 (TEMS2)
LU: LU dehumidifier heater abnormality C-0418 Dehumidifier heater /3 (DH2) temperature rise abnormality. The temperature detected by the temperature sensor /2 (TEMS2) has not risen to a prescribed level within a specified period of time. • LU drive board (LUDB)
• Main body AC drive board (ACDB)
• Dehumidification heater /3 (DH2)
• Temperature sensor /2 (TEMS2)
• AC drive assy
FS: FS abnormality C-1005 Communication error. The main body and the FS stop immediately to turn OFF the main relay (RL1). • Printer control board (PRCB)
• FNS control board (FNSCB)
FD: FD abnormality C-1006 Communication error. The main body and the FD stop immediately to turn OFF the main relay (RL1). • Printer control board (PRCB)
• FD control board (FDCB)
SD: SD abnormality C-1007 Communication error. The main body and the SD stop immediately to turn OFF the main relay (RL1). • Printer control board (PRCB)
• SD control board (SDCB)
PB: PB abnormality C-1009 Communication error between Main CPU in the PB control board (PBCB) and Sub CPU1. The main body and the PB stop immediately to turn OFF the main relay (RL1). • PB control board (PBCB)
• Control program
PB: PB abnormality C-1010 Communication error between Main CPU in the PB control board (PBCB) and Sub CPU2. • PB control board (PBCB)
• Control program
PB control board (PBCB) C-1011 Paper feed error between the main body and PB. • PB control board (PBCB)
• Control program
GP: GP abnormality C-1012 Communication abnormality. The main body and the RU stop immediately to turn OFF the main relay (RL1). • Printer control board (PRCB)
• Punch Controller PCB
RU: RU-509 abnormality C-1013 Communication error. The main body and the RU stop immediately to turn OFF the main relay (RL1). • Printer control board (PRCB)
• RU control board (RUCB)
RU: RU-506 abnormality C-1014 Communication abnormality. The main body and the RU stop immediately to turn OFF the main relay (RL1). • Printer control board (PRCB)
• RU control board (RUCB)
FS: FS-531/612 abnormality C-1101 (FS-531/612) The shift unit does not get to the shift position or the home position within a specified period of time. The main body and the FS stop immediately to turn OFF the main relay (RL1). • FNS control board (FNSCB)
• Shift roller motor (M2)
• Shift roller home sensor (PS18)
FS: FS-521 abnormality C-1102 (FS-521) The tray up down motor (M3) does not turn OFF even when a specified period of time elapses after it starts operations, or it operates for more than the allowed time at a speed out of the specified one. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Main tray up down motor (M3)
• Main tray upper limit sensor (PS2)
• Main tray lower limit sensor (PS3)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-531/612 abnormality C-1102 (FS-531/612) The main tray upper limit sensor (PS2) does not turn ON within a specified period of time after the main tray up down motor (M3) turns ON. • FNS control board (FNSCB)
• Main tray up down motor (M3)
• Main tray upper limit sensor (PS2)
FS: FS-521 abnormality C-1103 (FS-521) The alignment home sensors /Rr (PS5) and /Fr (PS31) do not turn ON within a specified period of time after the home position search operation of the alignment motors /Rr (M5) and /Fr (M22) starts. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Alignment motor /Rr (M5)
• Alignment motor /Fr (M22)
• Alignment home sensor /Rr (PS5)
• Alignment home sensor /Fr (PS31)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-531/612 abnormality C-1103 (FS-531/612) The alignment home sensor /Up (PS5) does not turn ON or OFF within a specified period of time after the alignment motor /Up (M5) turns ON. • Relay board (RB)
• Alignment motor /Up (M5)
• Alignment home sensor /Up (PS5)
FS: FS-521 abnormality C-1104 (FS-521) The main tray paper exit motor (M7) operates for more than the allowed time at a speed out of the specified one. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Main tray exit motor (M7)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-531/612 abnormality C-1104 (FS-531/612) A prescribed speed is not obtained within a specified period of time after the paper exit roller motor (M7) turns ON. • FNS control board (FNSCB)
• Paper exit roller motor (M7)
FS: FS-521 abnormality C-1105 (FS-521) The paper exit opening unit does not get to the specified opening position within a specified period of time after the paper exit opening motor (MB) starts operations. • FNS control board (FNSCB)
• Paper exit opening motor (MB)
• Paper exit opening home sensor (PS12)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-531/612 abnormality C-1105 (FS-531/612) The paper exit home sensor (PS12) does not turn ON or OFF within a specified period of time after the paper exit opening motor (M8) turns ON. • FNS control board (FNSCB)
• Paper exit opening motor (M8)
• Paper exit home sensor (PS12)
FS: FS-521 abnormality C-1106 (FS-521) The stapler movement home sensor (PS11) does not turn ON within a specified period of time after the home position search operation of the stapler movement motor (M11) starts. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Stapler movement motor (M11)
• Stapler movement home sensor (PS11)
DIPSW6-3 The use of staple is unavailable
FS: FS-531/612 abnormality C-1106 (FS-531/612) The stapler movement home sensor (PS11) does not turn ON within a specified period of time after the stapler movement motor (M11) turns ON. • Relay board (RB)
• Stapler movement motor (M11)
• Stapler movement home sensor (PS11)
FS: FS-521 abnormality (skew rotation) C-1107 (FS-521) The stapler rotation home sensor (PS14) does not turn ON within a specified period of time after the home position search operation of the stapler rotation motor (M4) starts. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Stapler rotation motor (M4)
• Stapler rotation home sensor (PS14)
DIPSW6-3 The use of staple is unavailable
FS: FS-612 abnormality C-1107 (FS-612) The clincher rotation home sensor (PS14) does not turn ON or OFF within a specified period of time after the clincher rotation motor (M4) turns ON. • Relay board (RB)
• Clincher rotation motor (M4)
• Clincher rotation home sensor (PS14)
FS: FS-521 abnormality (vertical rotation) C-1108 (FS-521) The stapler rotation home sensor (PS14) does not turn ON within a specified period of time after the home position search operation of the stapler rotation motor (M4) starts. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Stapler rotation motor (M4)
• Stapler rotation home sensor (PS14)
DIPSW6-3 The use of staple is unavailable
FS: FS-612 abnormality C-1108 (FS-612) The stapler rotation home sensor (PS13) does not turn ON within a specified period of time after the stapler rotation motor (M6) turns ON. • Relay board (RB)
• Stapler rotation motor (M6)
• Stapler rotation home sensor (PS13)
FS: FS-521 abnormality C-1109 (FS-521) After the stapler motor /Fr (M31) starts operations, it does not complete operations within a specified period of time, and the stapler home sensor /Fr (PS41) does not turn ON. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Stapler board (SB)
• Stapler motor /Fr (M31)
• Stapler home sensor /Fr (PS41)
DIPSW6-3 The use of staple is unavailable
FS: FS-531/612 abnormality C-1109 (FS-531/612) The stapler motor home sensor /Fr (PS31) does not turn ON within a specified period of time after the stapler motor /Fr (M14) turns ON. • Relay board (RB)
• Stapler motor /Fr (M14)
• Stapler motor home sensor /Fr (PS31)
FS: FS-521 abnormality C-1110 (FS-521) After the stapler motor /Rr (M30) starts operations, it does not complete operations within a specified period of time, and the stapler home sensor /Rr (PS40) does not turn ON. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Stapler board (SB)
• Stapler motor /Rr (M30)
• Stapler home sensor /Rr (PS40)
DIPSW6-3 The use of staple is unavailable
FS: FS-531/612 abnormality C-1110 (FS-531/612) The stapler motor home sensor /Rr (PS30) does not turn ON within a specified period of time after the stapler motor /Rr (M9) turns ON. • Relay board (RB)
• Stapler motor /Rr (M9)
• Stapler motor home sensor /Rr (PS30)
FS: FS-612 abnormality C-1111 (FS-612) The clincher motor home sensor /Fr (PS33) does not turn ON within a specified period of time after the clincher motor /Fr (M15) turns ON. • Relay board (RB)
• Clincher motor /Fr (M15)
• Clincher motor home sensor /Fr (PS33)
FS: FS-612 abnormality C-1112 (FS-612) The clincher motor home sensor /Rr (PS32) does not turn ON within a specified period of time after the clincher motor /Rr (M10) turns ON. • Relay board (RB)
• Clincher motor /Rr (M10)
• Clincher motor home sensor /Rr (PS32)
FS: FS-521 abnormality C-1113 (FS-521) After the home position search operation of the rear stopper motor (M26) starts, the rear stopper home sensor (PS35) does not turn ON within a specified period of time. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Rear stopper motor (M26)
• Rear stopper home sensor (PS35)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-612 abnormality C-1113 (FS-612) After the home position search operation of saddle stitching stopper motor (M18) starts, the saddle stitching stopper home sensor (PS23) does not turn ON within a specified period of time. • Relay board (RB)
• Saddle stitching stopper motor (M18)
• Saddle stitching stopper home sensor (PS23)
DIPSW18-5 The use of multi half folding, saddle stitching and multi tri-folding unavailable
FS: FS-612 abnormality C-1114 (FS-612) The alignment home sensor /Lw (PS24) does not turn ON within a specified period of time after the alignment motor /Lw (M16) turns ON. • Relay board (RB)
• Alignment motor /Lw (M16)
• Alignment home sensor /Lw (PS24)
DIPSW18-5 The use of multi half folding, saddle stitching and multi tri-folding unavailable
FS: FS-612 abnormality C-1115 (FS-612) The folding knife home sensor (PS22) does not turn ON within a specified period of time after the folding knife motor (M19) turns ON. • Relay board (RB)
• Folding knife motor (M19)
• Folding knife home sensor (PS22)
DIPSW18-5 The use of multi half folding, saddle stitching and multi tri-folding unavailable (FS not connected)
FS: FS-612 abnormality C-1116 (FS-612) A prescribed speed is not obtained within a specified period of time after the folding transfer motor (M20) turns ON. • Relay board (RB)
• Folding transfer motor (M20)
DIPSW18-5 The use of multi half folding, saddle stitching and multi tri-folding unavailable (FS not connected)
Pl: Pl abnormality C-1124 The tray upper limit sensor /Lw (PS209) or the tray lower limit sensor /Lw (PS210) does not turn ON within a specified period of time after the tray lift motor /Lw (M202) turns ON. • FNS control board (FNSCB)
• Pl drive board (PIDB)
• Tray lift motor /Lw (M202)
• Tray upper limit sensor /Lw (PS209)
• Tray lower limit sensor /Lw (PS210)
DIPSW18-6 Pl unusable (Pl not connected)
Pl: Pl abnormality C-1125 The tray upper limit sensor /Up (PS205) or the tray lower limit sensor /Up (PS204) does not turn ON within a specified period of time after the tray lift motor /Up (M201) turns ON. • FNS control board (FNSCB)
• Pl drive board (PIDB)
• Tray lift motor /Up (M201)
• Tray upper limit sensor /Up (PS205)
• Tray lower limit sensor /Up (PS204)
DIPSW18-6 Pl unusable (Pl not connected)
Pl: Pl abnormality C-1126 A prescribed speed is not obtained within a specified period of time after the conveyance motor (M203) turns ON. • FNS control board (FNSCB)
• Pl drive board (PIDB)
• Conveyance motor (M203)
DIPSW18-6 Pl unusable (Pl not connected)
PK: PK abnormality C-1127 The punch shift home sensor (PS303) does not turn ON within a specified period of time after the punch shift motor (M302) turns ON. • FNS control board (FNSCB)
• Punch drive board (PDB)
• Punch shift motor (M302)
• Punch shift home sensor (PS303)
DIPSW19-5 PK unusable (PK not connected)
PK: PK abnormality C-1132 The punch home sensor (PS301) does not turn ON within a specified period of time after the punch motor (M301) turns ON. • FNS control board (FNSCB)
• Punch drive board (PDB)
• Punch motor (M301)
• Punch home sensor (PS301)
DIPSW19-5 PK unusable (PK not connected)
FS: FS-531/612 abnormality C-1137 (FS-531/612) The gate home sensor (PS16) does not turn ON within a specified period of time after the gate motor (M12) turns ON. • FNS control board (FNSCB)
• Gate motor (M12)
• Gate home sensor (PS16)
FS: FS-521 abnormality C-1140 (FS-521) After the paper exit arm motor /Fr (M23) starts operations, it does not complete operations within a specified period of time, or operates for more than the allowed time at a speed out of the specified one, and the paper exit arm home sensor /Fr (PS9) does not turn ON. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Paper exit arm motor (M23)
• Paper exit arm home sensor (PS9)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-521 abnormality C-1141 (FS-521) The stack assist home sensor (PS32) does not turn ON within a specified period of time after the home position search operation of the stack assist motor (M24) starts. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Stack assist guide motor (M24)
• Stack assist home sensor (PS32)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-521 abnormality C-1142 (FS-521) The intermediate roller home sensor (PS33) does not turn ON even after a specified period of time after the intermediate roller open/close motor (M25) starts the home position search operation. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Alignment motor /Fr (M22)
• Alignment motor /Rr (M5)
• Intermediate roller release solenoid (SD7)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-521 abnormality C-1143 (FS-521) The conveyance motor (M1) does not turn ON when the start button is turned ON, or does not shift speed for each processing. • FNS control board (FNSCB)
• Conveyance motor (M1)
• Paper exit sensor (PS37)
• FNS entrance sensor (PS4)
DIPSW6-5 FS unusable (FS not connected)
FS: FS-521 abnormality C-1144 (FS-521) The paper exit alignment plate home sensor /Fr (PS18) does not turn ON within a specified period of time after the paper exit alignment motor /Fr (M15) starts the home position search operation. Or, even after a specified period of time after M15 starts the operation, it does not stop. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Paper exit alignment motor /Fr (M15)
• Paper exit alignment plate home sensor /Fr (PS18)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-521 abnormality C-1145 (FS-521) The paper exit alignment plate home sensor /Rr (PS19) does not turn ON within a specified period of time after the paper exit alignment motor /Rr (M14) starts the home position search operation. Or, even after a specified period of time after M14 starts the operation, it does not stop. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Paper exit alignment motor /Rr (M14)
• Paper exit alignment plate home sensor /Rr (PS19)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-521 abnormality C-1146 (FS-521) The bypass roller release home sensor (PS13) does not turn ON within a specified period of time after the bypass roller release motor (M12) starts the home position search operation. Or, even after a specified period of time after M12 starts the operation, it does not stop. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Bypass roller release motor (M12)
• Bypass roller release home sensor (PS13)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-521 abnormality C-1147 (FS-521) The paper exit alignment plate retraction home sensor (PS24) does not turn ON within a specified period of time after the paper exit alignment plate retraction motor (M18) starts the home position search operation. Or, even after a specified period of time after M18 starts the operation, it does not stop. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Paper exit alignment plate retraction motor (M18)
• Paper exit alignment plate retraction home sensor (PS24)
DIPSW6-4 FS main tray and stapling are not available
FS: FS-521 abnormality C-1148 (FS-521) The stacker entrance roller release home sensor (PS23) does not turn ON within a specified period of time after the stacker entrance roller release motor (M16) starts the home position search operation. Or, even after a specified period of time after M16 starts the operation, it does not stop. • FNS control board (FNSCB)
• FNS drive board (FNSDB)
• Stacker entrance roller release motor (M16)
• Stacker entrance roller release home sensor (PS23)
DIPSW6-4 FS main tray and stapling are not available
LS (1st tandem): LS abnormality C-1201 The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. The main body and the LS stop immediately to turn OFF the main relay (RL1). • Stacker tray up down motor (M1)
• LS control board (LSCB)
DIPSW6-6 LS (1st tandem) unusable
LS (1st tandem): LS abnormality C-1202 The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. • Shift unit motor (M5)
• LS control board (LSCB)
DIPSW6-6 LS (1st tandem) unusable
LS (1st tandem): LS abnormality C-1203 The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. • Alignment motor (M7)
• LS control board (LSCB)
DIPSW6-6 LS (1st tandem) unusable
LS (1st tandem): LS abnormality C-1204 The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON. • Grip conveyance motor (M4) DIPSW6-6 LS (1st tandem) unusable
LS (1st tandem): LS abnormality C-1205 The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. • Stacker tray up down motor (M1)
• Stacker tray upper limit switch (MS2)
DIPSW6-6 LS (1st tandem) unusable
LS (1st tandem): LS abnormality C-1206 The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. • Stacker tray up down motor (M1)
• Stacker tray lower limit switch (MS3)
DIPSW6-6 LS (1st tandem) unusable
LS (2nd tandem): LS abnormality C-1211 The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. • Stacker tray up down motor (M1)
• LS control board (LSCB)
DIPSW6-6 LS (2nd tandem) unusable
LS (2nd tandem): LS abnormality C-1212 The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. • Shift unit motor (M5)
• LS control board (LSCB)
DIPSW6-6 LS (2nd tandem) unusable
LS (2nd tandem): LS abnormality C-1213 The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. • Alignment motor (M7)
• LS control board (LSCB)
DIPSW6-6 LS (2nd tandem) unusable
LS (2nd tandem): LS abnormality C-1214 The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON. • Grip conveyance motor (M4) DIPSW6-6 LS (2nd tandem) unusable
LS (2nd tandem): LS abnormality C-1215 The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. • Stacker tray up down motor (M1)
• Stacker tray upper limit switch (MS2)
DIPSW6-6 LS (2nd tandem) unusable
LS (2nd tandem): LS abnormality C-1216 The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. • Stacker tray up down motor (M1)
• Stacker tray lower limit switch (MS3)
DIPSW6-6 LS (2nd tandem) unusable
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
FD: FD abnormality C-1221 The 1st folding cam home sensor (PS55) does not turn ON within a specified period of time after the 1st folding release motor (M14) turns ON. The main body and the FD stop immediately to turn OFF the main relay (RL1). • 1st folding release motor (M14)
• Folding drive board (FDB)
• 1st folding cam home sensor (PS55)
DIPSW6-0 The use of the folding function and the punch section is unavailable
C-1222 The 2nd folding cam home sensor (PS56) does not turn ON within a specified period of time after the 2nd folding release motor (M15) turns ON. • 2nd folding release motor (M15)
• Folding drive board (FDB)
• 2nd folding cam home sensor (PS56)
DIPSW6-0 The use of the folding function and the punch section is unavailable
C-1223 The 3rd folding cam home sensor (PS57) does not turn ON within a specified period of time after the 3rd folding release motor (M16) turns ON. • 3rd folding release motor (M16)
• Folding drive board (FDB)
• 3rd folding cam home sensor (PS57)
DIPSW6-0 The use of the folding function and the punch section is unavailable
C-1224 The 2 holes punch home sensor (PSS) does not turn OFF within a specified period of time after the 2-holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 2 holes punch home sensor (PSS) does not turn OFF. • Punch motor (M10)
• Punch drive board (PDB)
• 2 holes punch home sensor (PSS)
DIPSW6-0 The use of the folding function and the punch section is unavailable
C-1225 The 3 holes/4 holes punch home sensor (PS9) does not turn OFF within a specified period of time after the 3 holes/4 holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 3 holes/4 holes punch home sensor (PS9) does not turn OFF. • Punch motor (M10)
• Punch drive board (PDB)
• 3 holes/4 holes home sensor (PS9)
DIPSW6-0 The use of the folding function and the punch section is unavailable
C-1226 The alignment plate home sensor (PS10) does not turn ON within a specified period of time after the alignment plate home position return operation starts. Or, after the alignment motor (M12) turns ON, the alignment plate home sensor (PS10) does not turn OFF. • Alignment motor (M12)
• Punch drive board (PDB)
• Alignment plate home sensor (PS10)
DIPSW6-0 The use of the folding function and the punch section is unavailable
C-1227 The punch registration home sensor (PS11) does not turn ON within a specified period of time after the punch registration claw home position return operation starts. Or, after the punch registration motor (M13) turns ON, the punch registration home sensor (PS11) does not turn OFF. • Punch registration motor (M13)
• Punch drive board (PDB)
• Punch registration home sensor (PS11)
DIPSW6-0 The use of the folding function and the punch section is unavailable
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
FD: FD abnormality C-1228 The main tray upper limit sensor (PS20) does not turn ON within a specified period of time after the main tray home position search starts. Or, after the tray up down motor (M11) turns ON, the main tray upper limit sensor (PS20) does not turn OFF. • Tray up down motor (M11)
• Main tray upper limit sensor (PS20)
• Punch drive board (PDB)
DIPSW6-1 Main tray unusable
C-1229 The main tray lower limit sensor (PS22) does not turn ON within a specified period of time after the tray up down motor (M11) is in the down operation. • Tray up down motor (M11)
• Punch drive board (PDB)
• Main tray lower limit sensor (PS22)
DIPSW6-1 Main tray unusable
C-1230 After the FD paper lift motor /Up (M8) is in the down operation, the Pl lift plate home sensor /Up (PS34) does not turn ON within a specified period of time. Or, after the paper lift motor /Up (M8) is in the up operation, the Pl tray upper limit sensor /Up (PS32) does not turn ON. • Paper lift motor /Up (M8)
• Pl drive board (PIDB)
• Pl lift plate home sensor /Up (PS34)
• Pl upper limit sensor /Up (PS32)
DIPSW6-2 The use of the Pl section unavailable
C-1231 After the FD paper lift motor /Lw (M9) is in the down operation, the Pl lift plate home sensor /Lw (PS40) does not turn ON within a specified period of time. Or, after the paper lift motor /Lw (M9) is in the up operation, the Pl upper limit sensor /Lw (PS38) does not turn ON. • Paper lift motor /Lw (M9)
• Pl drive board (PIDB)
• Pl lift plate home sensor /Lw (PS40)
• Pl upper limit sensor /Lw (PS38)
DIPSW6-2 The use of the Pl section unavailable
C-1232 An error detection signal is detected continuously for a specified period of time while the entrance conveyance motor (M1) is ON. • Paper lift motor /Lw (M9)
• Pl drive board (PIDB)
• Pl lift plate home sensor /Lw (PS40)
• Pl upper limit sensor /Lw (PS38)
C-1233 An error detection signal of M3 is detected continuously for a specified period of time while the intermediate conveyance motor (M3) is ON. • Intermediate conveyance motor (M3)
• Punch drive board (PDB)
C-1234 An error detection signal of M7 is detected continuously for a specified period of time while the Pl conveyance motor (M7) is ON. • Pl conveyance motor (M7)
• Pl drive board (PIDB)
DIPSW6-2 The use of the Pl section unavailable
C-1235 An error detection signal of M17 is detected continuously for a specified period of time while the main tray exit motor (M17) is ON. • Main tray exit motor (M17)
• Punch drive board (PDB)
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
SD: SD abnormality C-1241 The scraps press home sensor (PS48) does not turn ON within a specified period of time after the bundle exit motor (M5) starts the home position search operation. The main body and the SD stop immediately to turn OFF the main relay (RL1). • Bundle exit motor (M5)
• Scraps press home sensor (PS48)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1242 The folding main scan alignment home sensor /Fr1 (PS18) does not turn ON within a specified period of time after the folding main scan alignment motor /Fr (M7) starts the home position search operation. Or, even after a specified period of time after M7 starts the operation, it does not stop. • Folding main scan alignment motor /Fr (M7)
• Folding main scan alignment home sensor /Fr1 (PS18)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding, multi tri-folding and trimmer unavailable
C-1243 The folding exit home sensor (PS24) does not turn ON within a specified period of time after the folding sub scan alignment exit motor (M8) starts the home position search operation. Or, even after a specified period of time after M8 starts to decelerate, it does not stop. • Folding sub scan alignment exit motor (M8)
• Folding exit home sensor (PS24)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding, multi tri-folding and trimmer unavailable
C-1244 The saddle stitching alignment home sensor /Rt (PS28) does not turn ON within a specified period of time after the saddle stitching alignment motor /Rt (M9) starts the home position search operation. Or, even after a specified period of time after M9 starts the operation, it does not stop. • Saddle stitching alignment motor /Rt (M9)
• Saddle stitching alignment home sensor /Rt (PS28)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1245 The bundle arm home sensor (PS32) does not turn ON within a specified period of time after the bundle arm motor (M10) starts the home position search operation. Or, even after a specified period of time after M10 starts the operation, it does not stop. • Bundle arm motor (M10)
• Bundle arm home sensor (PS32)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1246 The bundle clip upper limit sensor (PS33) does not turn ON within a specified period of time after the bundle clip motor (M11) starts the home position search operation. Or, even after a specified period of time after M11 starts the operation, it does not stop. • Bundle clip motor (M11)
• Bundle clip upper limit sensor (PS33)
• Bundle clip lower limit sensor (PS30)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1247 The bundle registration home sensor (PS34) does not turn ON within a specified period of time after the bundle registration motor (M12) starts the home position search operation. Or, even after a specified period of time after M12 starts the operation, it does not stop. • Bundle registration motor (M12)
• Bundle registration home sensor (PS34)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
SD: SD abnormality C-1248 The overlap home sensor (PS17) does not turn ON within a specified period of time after the overlap motor (M13) starts the home position search operation. Or, even after a specified period of time after M13 starts the operation, it does not stop. • Overlap motor (M13)
• Overlap home sensor (PS17)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding, multi tri-folding and trimmer unavailable
C-1249 The folding main scan alignment home sensor /Rr (PS19) does not turn ON within a specified period of time after the folding main scan alignment motor /Rr (M14) starts the home position search operation. Or, even after a specified period of time after M14 starts the operation, it does not stop. • Folding main scan alignment motor /Rr (M14)
• Folding main scan alignment home sensor /Rr (PS19)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding, multi tri-folding and trimmer unavailable
C-1250 The stapler movement home sensor (PS25) does not turn ON within a specified period of time after the home position search operation of the stapler movement motor (M15) starts. Or, even after a specified period of time after M15 starts the operation, it does not stop. • Stapler movement motor (M15)
• Stapler movement home sensor (PS25)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1251 The saddle stitching alignment home sensor /Lt (PS29) does not turn ON within a specified period of time after the saddle stitching alignment motor /Lt (M16) starts the home position search operation. Or, even after a specified period of time after M16 starts the operation, it does not stop. • Saddle stitching alignment motor /Lt (M16)
• Saddle stitching alignment home sensor /Lt (PS29)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1252 The bundle press movement home sensor (PS36) does not turn ON within a specified period of time after the bundle press movement motor (M17) starts the home position search operation. Or, even after a specified period of time after M17 starts the operation, it does not stop. • Bundle press movement motor (M17)
• Bundle press movement home sensor (PS36)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1253 The 1st folding blade home sensor (PS21) does not turn ON within a specified period of time after the 1st folding blade motor (M18) starts the home position search operation. Or 1st folding blade home sensor /1 (PS20) does not turned ON within a specified period of time after M18 starts the operation. • 1st folding blade motor (M18)
• 1st folding blade home sensor /1 (PS20), /2 (PS21)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding, multi tri-folding and trimmer unavailable
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
SD: SD abnormality C-1254 The 2nd folding blade home sensor /2 (PS23) does not turn ON within a specified period of time after the 2nd folding blade motor (M19) starts the home position search operation. Or the 2nd folding blade home sensor /1 (PS22) does not turned ON within a specified period of time after M19 starts the operation. • 2nd folding blade motor (M19)
• 2nd folding blade home sensor /1 (PS22), /2 (PS23)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-2 The use of the multi tri-folding unavailable
C-1255 The clincher up down home sensor (PS26) does not turn ON even after a specified period of time after the clincher up down motor (M20) starts the home position search. Or, even after a specified period of time after M20 starts the operation, it does not stop. • Clincher up down motor (M20)
• Clincher up down home sensor (PS26)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1256 The saddle stitching press home sensor (PS27) does not turn ON within a specified period of time after the saddle stitching press motor (M21) starts the home position search operation. Or, even after a specified period of time after M21 starts the operation, it does not stop. • Saddle stitching press motor (M21)
• Saddle stitching press home sensor (PS27)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1257 The bundle arm rotation home sensor (PS31) does not turn ON within a specified period of time after the bundle arm rotation motor (M22) starts the home position search operation. Or, even after a specified period of time after M22 starts the operation, it does not stop. • Bundle arm rotation motor (M22)
• Bundle arm rotation home sensor (PS31)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1258 The bundle press home sensor (PS37) does not turn ON within a specified period of time after the bundle press motor (M23) starts the home position search operation. Or, even after a specified period of time after M23 starts the operation, it does not stop. • Bundle press motor (M23)
• Bundle press home sensor (PS37)
• Bundle press lower limit sensor (PS47)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1259 The bundle press home sensor (PS35) does not turn ON within a specified period of time after the bundle press stage up down motor (M24) starts the home position search operation. Or PS35 or the bundle press stage up down upper limit sensor (PS45) does not turned ON after a specified period of time M24 starts the operation. • Bundle press stage up down motor (M24)
• Bundle press stage up down home sensor (PS35)
• Bundle press stage up down limit sensor (PS45)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0 The use of the saddle stitching, multi center folding and trimmer unavailable
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
SD: SD abnormality C-1260 The guide shaft home sensor (PS46) does not turn ON even after a specified period of time after the guide shaft motor (M25) starts the home position search operation. Or, even after a specified period of time after M25 starts the operation, it does not stop. • Guide shaft motor (M25)
• Guide shaft home sensor (PS46)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0, DIPSW7-1, DIPSW7-3 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1261 The stapler home sensor /Rt (HS1) or the clincher start sensor /Rt (HS2) does not turn ON even after a specified period of time after the stapler motor /Rt (M29) starts the operation. • Stapler assembly /Rt
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0, DIPSW7-3 The use of the saddle stitching and trimmer unavailable
C-1262 The stapler home sensor /Lt (HS3) or the clincher start sensor /Lt (HS4) does not turn ON even after a specified period of time after the stapler motor /Lt (M30) starts the operation. • Stapler assembly /Lt
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0, DIPSW7-3 The use of the saddle stitching and trimmer unavailable
C-1263 It does not stop even after a specified period of time after the trimmer blade motor (M31) starts the operation. • Trimmer blade motor (M31)
• Trimmer blade home sensor (PS50)
• Trimmer blade upper limit sensor (PS51)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-3 The use of the trimmer unavailable
C-1264 It does not stop even after a specified period of time after the trimmer press motor (M32) starts the operation. • Trimmer press motor (M32)
• Trimmer press home sensor (PS53)
• Trimmer press upper limit sensor (PS52)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0, DIPSW7-1, DIPSW7-3 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1265 It does not stop even after a specified period of time after the bundle arm assist motor (M26) starts the operation. • Bundle arm assist motor (M26)
• Bundle arm assist home sensor (PS38)
• Bundle arm assist upper limit sensor (PS39)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0, DIPSW7-1, DIPSW7-3 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1266 Rotation abnormality is detected for a specified period of time in succession while the entrance conveyance motor (M1) is driving. • Entrance conveyance motor (M1)
• SD control board (SDCB)
• SD drive board (SDDB)
C-1267 Rotation abnormality is detected for a specified period of time in succession while the horizontal conveyance motor (M2) is driving. • Horizontal conveyance motor (M2)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-4 Sub tray, paper exit to subsequent stage and FS unavailable
C-1268 Rotation abnormality is detected for a specified period of time in succession while the folding entrance motor (M3) is driving. • Folding entrance motor (M3)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0, DIPSW7-1, DIPSW7-2, DIPSW7-3 The use of the saddle stitching, multi center folding, multi tri-folding and trimmer unavailable
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
SD: SD abnormality C-1269 Rotation abnormality is detected for a specified period of time in succession while the folding transfer motor (M4) is driving. • Folding transfer motor (M4)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0, DIPSW7-1, DIPSW7-2, DIPSW7-3 The use of the saddle stitching, multi center folding, multi tri-folding and trimmer unavailable
C-1270 Rotation abnormality is detected for a specified period of time in succession while the bundle exit motor (M5) is driving. • Bundle exit motor (M5)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0, DIPSW7-1, DIPSW7-3 The use of the saddle stitching, multi center folding and trimmer unavailable
C-1271 Rotation abnormality is detected for a specified period of time in succession while the folding sub scan alignment exit motor (M8) is driving. • Folding sub scan alignment exit motor (M8)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-0, DIPSW7-1, DIPSW7-2, DIPSW7-3 The use of the saddle stitching, multi center folding, multi tri-folding and trimmer unavailable
C-1272 Rotation abnormality is detected for a specified period of time in succession while the trimmer paddle motor (M33) is driving. • Trimmer paddle motor (M33)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-3 The use of the trimmer unavailable
C-1273 The trimmer completion sensor (PS62) does not turn ON even after a specified period of time after the trimmer blade motor (M31) is in the up operation. • Trimmer blade motor (M31)
• Trimmer completion sensor (PS62)
• SD control board (SDCB)
• SD drive board (SDDB)
DIPSW7-3 The use of the trimmer unavailable
C-1275 The wire slack sensor (PS66) detected the slack of the trimmer edge drive wire. • Wire slack prevention sensor (PS66)
• SD control board (SDCB)
• SD drive board (SDDB)
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
RU: RU-506 abnormality C-1281 FD alignment motor (M3) drive abnormality. The FD alignment home sensor (PS3) does not turn ON even after a specified period of time after M3 starts the home position search operation. Or, even after a specified period of time after M3 starts the operation, it does not stop. Main body and RU stop immediately and main relay (RY1) is turned OFF. • RU control board (RUCB)
• FD alignment motor (M3)
• FD alignment home sensor (PS3)
C-1282 CD alignment motor (M4) drive abnormality. The CD alignment home sensor (PS4) does not turn ON even after a specified period of time after M4 starts the home position search operation. Or, even after a specified period of time after M4 starts the operation, it does not stop. • RU control board (RUCB)
• CD alignment motor (M4)
• CD alignment home sensor (PS4)
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
RU: RU-509 abnormality C-1290 Rotation abnormality is detected for a specified period of time in succession while the de-curler conveyance motor (M3) is driving. The main body and the RU stop immediately to turn OFF the main relay (RL1). • De-curler conveyance motor (M3)
• RU control board (RUCB)
Classification Malfunction code Cause Resulting operation Estimated abnormal parts DIPSW Control when
RU abnormality C-1291 The home position search operation of the de-curler pressure motor /Lw (M5) does not complete within a specified period of time. De-curler pressure motor /Lw (M5)
RU control board (RUCB)
RU abnormality C-1292 The home position search operation of the de-curler pressure motor /Up (M6) does not complete within a specified period of time. De-curler pressure motor /Up (M6)
RU control board (RUCB)
RU abnormality C-1293 Rotation abnormality is detected while the humidification section conveyance motor (M8) is driving. Humidification section conveyance motor (M8)
RU control board (RUCB)
DIPSW13-2 Humidification unusable
RU abnormality C-1294 The home position search operation of the humidification section roller pressure motor /Rt (M9) does not complete. Roller pressure motor /Rt (M9)
RU control board (RUCB)
DIPSW13-2 Humidification unusable
RU abnormality C-1295 The home position search operation of the humidification roller pressure motor /Lt (M10) does not complete. Roller pressure motor /Lt (M10)
RU control board (RUCB)
DIPSW13-2 Humidification unusable
RU abnormality C-1296 Color density sensor detection preparation adjustment value abnormality. Color density sensor unit
Color density control board (CDCB)
RU control board (RUCB)
DIPSW13-3 Color density sensor unusable
RU abnormality C-1297 Color density sensor detection start abnormality. Shutter solenoid (SD5)
Color density sensor unit
CDCB
RUCB
DIPSW13-3 Color density sensor unusable
RU abnormality C-1298 EEPROM read out abnormality in the color density relay board. Color density control board (CDCB)
RU control board (RUCB)
DIPSW13-3 Color density sensor unusable
RU abnormality C-1299 Water tank full sensor (PS13) remains ON longer than specified. Drain path
Water tank full sensor (PS13)
RU control board (RUCB)
DIPSW13-2 Humidification unusable
LS (1st tandem) C-1301 Error detected while paper cooling fan motor /Fr (FM1) is ON. Main body and LS stop Paper cooling fan motor (FM1)
LS control board (LSCB)
LS (1st tandem) C-1302 Error detected while paper cooling fan motor /1 (FM2) is ON. Paper cooling fan motor (FM2)
LSCB
LS (1st tandem) C-1303 Error detected while paper cooling fan motor /Mi (FM3) is ON. Paper cooling fan motor (FM3)
LSCB
PB abnormality C-1330 Rotation error while cover paper tray fan /1 (FM71) is operating. Main body and PB stop PB control board (PBCB)
PB drive board (PBDB)
Fan FM71
DIPSW7-5 PB paper feed unavailable
PB abnormality C-1331 Rotation error while cover paper tray fan /2 (FM72) is operating. PBCB
PBDB
Fan FM72
DIPSW7-5 PB paper feed unavailable
PB abnormality C-1332 Rotation error while exhaust fan /1 (FM80) is operating. PBCB
PBDB
Fan FM80
DIPSW7-6 Sub tray eject available
PB abnormality C-1333 Rotation error while exhaust fan /2 (FM81) is operating. ACDB
PBCB
PBDB
Fan FM81
DIPSW7-6 Sub tray eject available
Classification Malfunction code Cause Resulting operation Estimated abnormal parts DIPSW Control when
PB abnormality C-1334 Rotation error detected while pellet supply cooling fan (FM4) is operating. AC drive board (ACDB)
PBCB
PBDB
Pellet supply cooling fan (FM4)
DIPSW7-6 Ejecting onto sub tray possible
RU-506 abnormality C-1341 Stack assist fan /Fr (FM1) rotation abnormality. Main body and RU stop RU control board (RUCB)
Stack assist fan /Fr (FM1)
RU-506 abnormality C-1342 Stack assist fan /Rr (FM2) rotation abnormality. RU control board (RUCB)
Stack assist fan /Rr (FM2)
RU-509 abnormality C-1351 Error detected while entrance paper fans FM1–FM3 are ON. Main body and RU stop Entrance paper fans FM1–FM3
RUCB
RU-509 abnormality C-1352 Error detected while ventilation assist fans FM4 and FM5 are ON. Ventilation assist fans FM4, FM5
RUCB
RU-509 abnormality C-1353 Error detected while entrance paper fans FM15–FM17 are ON. Entrance paper fans FM15–FM17
RUCB
RU-9 abnormality C-1354 Error detected while entrance paper fans FM18–FM20 are ON. Entrance paper fans FM18–FM20
RUCB
RU-9 abnormality C-1355 Error detected while ventilation assist fan FM21 is ON. Jumper connector CN180
Ventilation assist fan FM21
RUCB
RU-509 abnormality C-1356 Error detected while humidification paper fan /1 (FM6) is ON. Humidification paper fan FM6
RUCB
DIPSW13-2 Humidification unusable
RU-509 abnormality C-1357 Error detected while humidification paper fan /2 (FM7) is ON. Humidification paper fan FM7
RUCB
DIPSW13-2 Humidification unusable
RU-509 abnormality C-1358 Error detected while humidification paper fan /3 (FM8) is ON. Humidification paper fan FM8
RUCB
DIPSW13-2 Humidification unusable
RU-509 abnormality C-1359 Error detected while humidification paper fan /4 (FM9) is ON. Humidification paper fan FM9
RUCB
DIPSW13-2 Humidification unusable
RU-509 abnormality C-1360 Error detected while humidification paper fan /5 (FM10) is ON. Humidification paper fan FM10
RUCB
DIPSW13-2 Humidification unusable
RU-509 abnormality C-1361 Error detected while humidification paper fan /6 (FM11) is ON. Humidification paper fan FM11
RUCB
DIPSW13-2 Humidification unusable
FS abnormality C-1402 Non-volatile memory abnormality. Main body and FS stop FS control board (LSCB)
FNS control board (FNSCB)
FD abnormality C-1403 Non-volatile memory abnormality. Main body and FD stop FD control board (FDCB)
SD abnormality C-1404 Non-volatile memory abnormality. Main body and SD stop SD control board (SDCB)
PB abnormality C-1406 Non-volatile memory abnormality in PB control board. Main body and PB stop PB control board (PBCB)
Control program
RU abnormality C-1407 Non-volatile memory abnormality. Main body and RU stop RU control board (RUCB)
RU abnormality C-1408 Non-volatile memory error. Main body and RU stop RU control board (RUCB)
Classification Malfunction code Cause Resulting operation Estimated abnormal parts DIPSW Control when
RU-509 abnormality C-1455 When RU is unready, a signal to start operations is received from the main body. Main body and RU stop immediately Software bug
RU-506 abnormality C-1456 RU received operation start signal from the main body when RU is unready. Main body and RU stop immediately Software bug
PB abnormality C-1501 The entrance conveyance is not completed within a specified time after entrance conveyance motor (M1) turns ON. Main body and PB stop immediately PB control board (PBCB)
PB drive board (PBDB)
Entrance conveyance motor (M1)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1502 Rotation error detected continuously while intermediate conveyance motor (M2) is driving. PB control board (PBCB)
PB drive board (PBDB)
Intermediate conveyance motor (M2)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1504 The SC entrance conveyance is not completed within a specified time after SC entrance conveyance motor (M11) turns ON. PB control board (PBCB)
PB drive board (PBDB)
SC entrance conveyance motor (M11)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1505 The switchback conveyance is not completed within a specified time after SC switchback conveyance motor (M12) turns ON. PB control board (PBCB)
PB drive board (PBDB)
SC switchback conveyance motor (M12)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1506 The switchback roller release operation is not completed within a specified time after SC switchback release motor (M13) turns ON. PB control board (PBCB)
PB drive board (PBDB)
SC switchback release motor (M13)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1507 The SC alignment is not completed within a specified time after SC alignment motor (M15) turns ON. PB control board (PBCB)
PB drive board (PBDB)
SC alignment motor (M15)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1508 The SC paper bundle conveyance is not completed within a specified time after SC bundle conveyance motor (M17) turns ON. PB control board (PBCB)
PB drive board (PBDB)
SC bundle conveyance motor (M17)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1509 The SC roller release operation is not completed within a specified time after SC roller release motor (M18) turns ON. PB control board (PBCB)
PB drive board (PBDB)
SC roller release motor (M18)
DIPSW7-6 Ejecting onto the sub tray is possible
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
PB abnormality C-1510 The SC entrance movement operation has not been completed within a specified time after the clamp entrance movement motor (M19) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Clamp entrance movement motor (M19)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1511 The clamp entrance roller release operation has not been completed within a specified time after the clamp entrance roller release motor (M20) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Clamp entrance roller release motor (M20)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1512 The clamp alignment has not been completed within a specified time after clamp alignment motor (M21) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Clamp alignment motor (M21)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1513 The clamp section open/close operation has not been completed within a specified time after the clamp motor (M22) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Clamp motor (M22)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1514 The clamp rotation operation has not been completed within a specified time after the clamp rotation motor (M23) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Clamp rotation motor (M23)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1515 The glue tank movement operation has not been completed within a specified time after the glue tank movement motor (M31) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Glue tank movement motor (M31)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1516 A rotation error detection signal is detected continuously while the glue apply roller motor (M32) is driving. PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1517 The counted number of pellets by pellet supply passage sensor (PS37) is not reached after pellet supply pipe motor (M33) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Pellet supply pipe motor (M33)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1518 The operation of the pellet supply arm has not been completed within a specified time after pellet supply arm motor (M34) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Pellet supply arm motor (M34)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1519 The alignment in the cover paper table up/down section has not been completed within a specified time after cover paper alignment motor (M41) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper alignment motor (M41)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1520 The booklet exit has not been completed within a specified time after booklet exit motor (M42) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Booklet exit motor (M42)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1521 The driven arm /Rt swing operation has not been completed after cover paper conveyance arm motor /Rt (M43) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper conveyance arm motor /Rt (M43)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1522 The driven arm /Lt swing operation has not been completed after cover paper conveyance arm motor /Lt (M44) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper conveyance arm motor /Lt (M44)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1523 The cover paper conveyance start has not been completed after cover paper conveyance motor (M45) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper conveyance motor (M45)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1524 The cover paper table up/down movement has not been completed after cover paper table up/down motor /Fr (M46) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper table up/down motor /Fr (M46)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1525 The cover paper table up/down movement has not been completed after cover paper table up/down motor /Rr (M47) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper table up/down motor /Rr (M47)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1526 The movement of the cover paper folding plate /Rt has not been completed after cover paper folding motor /Rt (M48) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper folding motor /Rt (M48)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1527 The movement of the cover paper folding plate /Lt has not been completed after cover paper folding motor /Lt (M49) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper folding motor /Lt (M49)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1528 The trimming of the cover paper has not been completed after cutter motor (M50) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cutter motor (M50)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1530 The booklet movement has not been completed after booklet conveyance belt motor (M61) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Booklet conveyance belt motor (M61)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1531 The size changing operation has not been completed after booklet conveyance belt movement motor (M62) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Booklet conveyance belt movement motor (M62)
DIPSW7-6 Ejecting onto the sub tray is possible
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
PB abnormality C-1532 The up/down movement operation of the carriage section has not been completed within a specified period of time after the booklet conveyance belt up/down motor (M63) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Booklet conveyance belt up/down motor (M63)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1534 The booklet rear edge pressing process has not been completed within a specified period of time after the booklet stopper motor (M65) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Booklet stopper motor (M65)
DIPSW7-6 Ejecting onto the sub tray is possible
PB abnormality C-1537 The tray moving up process has not been completed within a specified period of time after the cover paper tray lift motor (M73) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper tray lift motor (M73)
DIPSW7-5 Paper feed from the PB is unavailable
PB abnormality C-1538 The cover paper feed has not been completed within a specified period of time after the cover paper feed motor (M74) turns ON. PB control board (PBCB)
PB drive board (PBDB)
Cover paper feed motor (M74)
DIPSW7-5 Paper feed from the PB is unavailable
PB abnormality C-1540 After warm-up starts, the glue tank temperature sensor /Md (TH3) does not reach the prescribed temperature within a specified time. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Md (TH3)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1541 After warm-up starts, the glue tank temperature sensor /Lw (TH4) does not reach the prescribed temperature within a specified time. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Lw (TH4)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1542 After warm-up starts, the glue apply roller temperature sensor (TH1) does not reach the prescribed temperature within a specified time. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue apply roller temperature sensor (TH1)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1543 After pellet supply, the glue tank temperature sensor /Up (TH2) does not reach the prescribed temperature within a specified time. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Up (TH2)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1544 During standby, after glue tank heater (H1) turns ON, the glue tank temperature sensor /Md (TH3) does not reach the prescribed temperature within a specified time. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Md (TH3)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1545 After reaching prescribed temperature, glue tank temperature sensor /Lw (TH4) does not rise to the required level within a specified time. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Lw (TH4)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1546 After reaching prescribed temperature, glue apply roller temperature sensor (TH1) does not rise to the required level within a specified time. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue apply roller temperature sensor (TH1)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1547 The glue apply roller temperature sensor (TH1) detects an abnormal high temperature. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue apply roller temperature sensor (TH1)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1548 The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Up (TH2)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1549 The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Md (TH3)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1550 The glue tank temperature sensor /Lw (TH4) detects an abnormal high temperature. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Lw (TH4)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1551 The glue apply roller temperature sensor (TH1) detects an abnormal high temperature (hardware). AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue apply roller temperature sensor (TH1)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1552 The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature (hardware). AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Up (TH2)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1553 The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature (hardware). AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Md (TH3)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1554 The glue tank temperature sensor /Lw (TH4) detects an abnormal high temperature (hardware). AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Lw (TH4)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1555 After warm-up is completed, the glue apply roller temperature sensor (TH1) detects an abnormal low temperature. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue apply roller temperature sensor (TH1)
DIPSW7-7 The use of the PB is unavailable
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
PB abnormality C-1556 When glue supply control temperature is reached, the glue tank temperature sensor /Up (TH2) detects an abnormal low temperature. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Up (TH2)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1557 After warming-up is completed, the glue tank temperature sensor /Md (TH3) detects an abnormal low temperature. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Md (TH3)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1558 After warming-up is completed, the glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature. AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Lw (TH4)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1559 The glue apply roller temperature sensor (TH1) detects an abnormal low temperature (hardware). The main body stops immediately to turn OFF the main relay (RL1). AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue apply roller temperature sensor (TH1)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1560 The glue tank temperature sensor /Up (TH2) detects an abnormal low temperature (hardware). The main body and the PB stop immediately to turn OFF the main relay (RL1). AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Up (TH2)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1561 The glue tank temperature sensor /Md (TH3) detects an abnormal low temperature (hardware). AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Md (TH3)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1562 The glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature (hardware). AC drive board (ACDB)
Glue tank heater (H1)
Glue apply roller heater (H2)
PB control board (PBCB)
PB drive board (PBDB)
Glue apply roller motor (M32)
Glue tank temperature sensor /Lw (TH4)
DIPSW7-7 The use of the PB is unavailable
PB abnormality C-1565 Relay conveyance motor drive abnormality. The main body and the PB stop immediately to turn OFF the main relay (RL1). Relay conveyance motor (M92)
PB control board (PBCB)
PB drive board (PBDB)
PB abnormality C-1566 Relay conveyance exit motor drive abnormality. The main body and the PB stop immediately to turn OFF the main relay (RL1). Relay conveyance exit motor (M91)
PB control board (PBCB)
PB drive board (PBDB)
PB abnormality C-1567 Pellet supply pipe motor drive abnormality. Pellet supply pipe motor (M33)
PB control board (PBCB)
PB drive board (PBDB)
Main body: Communication error C-2001 Communication error between PRCB and drum motor /Y (M14). The main body stops immediately to turn OFF the power relay (RL1). Printer control board (PRCB)
Drum motor /Y (M14)
Drum motor /M (M15)
Main body: Communication error C-2003 Communication error between PRCB and belt motor (M18). Printer control board (PRCB)
Belt motor (M18)
Main body: Communication error C-2004 Communication error between PRCB and drum motors /Y (M14) or /M (M15). Printer control board (PRCB)
Drum motor /Y (M14)
Drum motor /M (M15)
Main body: Communication error C-2006 Communication error between PRCB and belt motor (M18). Printer control board (PRCB)
Belt motor (M18)
Main body: Developing motor abnormality C-2201* Rotation error detected while developing motor /Y (M20) is ON. Printer control board (PRCB)
Developing motor /Y (M20)
Main body: Developing motor abnormality C-2202* Rotation error detected while developing motor /M (M21) is ON. Printer control board (PRCB)
Developing motor /M (M21)
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
Main body: Developing motor abnormality C-2203* An error detection signal of M22 is detected continuously for a specified period of time while the developing motor IC (M22) is ON. Printer control board (PRCB)
Developing motor IC (M22)
Main body: Developing motor abnormality C-2204* An error detection signal of M23 is detected continuously for a specified period of time while the developing motor IK (M23) is ON. Printer control board (PRCB)
Developing motor IK (M23)
Main body: Transfer belt unit abnormality C-2220 An error detection signal of M18 is detected continuously for a specified period of time while the belt motor (M18) is ON. Printer control board (PRCB)
Belt motor (M18)
Encoder sensor belt 11 (PS89), 12 (PS90)
DC power supply 12 (DCPS2)
Intermediate transfer unit
Main body: 1st transfer motor abnormality C-2221 While the 1st transfer HP sensor (PS15) is ON, PS15 does not turn OFF within a specified period of time after M19 turns ON. Or PS15 does not turn ON within a specified period of time. AC drive board (ACDB)
Printer control board (PRCB)
1st transfer pressure release motor (M19)
1st transfer HP sensor (PS15)
Main body: Toner supply abnormality C-2222 Error detection signal is detected for a specified period of time while toner supply motors and toner bottle motors are ON. Printer control board (PRCB)
Toner supply drive board (TSDB)
Toner supply motors (M49–M52)
Toner bottle motor (M53)
Toner bottle clutches (CL14–CL17)
Main body: Low drum load torque abnormality C-2223 Drum motor torque is not recovered within a specified period of time. The main body stops immediately to turn OFF the power relay (RL1). Drum motors (M14–M17)
Printer control board (PRCB)
Main body: Drum motor abnormality C-2231* Error detection signal of drum motor /Y (M14) is detected continuously. The main body stops immediately to turn OFF the power relay (RL1). Printer control board (PRCB)
Drum motor /Y (M14)
Encoder sensors PS81, PS82
DC power supply 12 (DCPS2)
Drum unit /Y
Main body: Drum motor abnormality C-2232* Error detection signal of drum motor IM (M15) is detected continuously. Printer control board (PRCB)
Drum motor IM (M15)
Encoder sensors PS83, PS84
DC power supply 12 (DCPS2)
Drum unit IM
Main body: Drum motor abnormality C-2233* Error detection signal of drum motor IC (M16) is detected continuously. Printer control board (PRCB)
Drum motor IC (M16)
Encoder sensors PS85, PS86
DC power supply 12 (DCPS2)
Drum unit IC
Main body: Drum motor abnormality C-2234* Error detection signal of drum motor IK (M17) is detected continuously. Printer control board (PRCB)
Drum motor IK (M17)
Encoder sensors PS87, PS88
DC power supply 12 (DCPS2)
Drum unit IK
Main body: Fan abnormality C-2301 Error detection signal of charge intake fan (FM48) is detected continuously. The main body stops immediately to turn OFF the power relay (RL1). Printer control board (PRCB)
Toner supply drive board (TSDB)
Charge intake fan (FM48)
Main body: Fan abnormality C-2302* Error detection signal of motor cooling fan 11 (FM12) is detected continuously. Printer control board (PRCB)
Motor cooling fan 11 (FM12)
Main body: Fan abnormality C-2303* Error detection signal of transfer belt fan (FM11) is detected continuously. Printer control board (PRCB)
Transfer belt fan (FM11)
Main body: Fan abnormality C-2304* Error detection signal of developing fan 11 (FM45) is detected continuously. Printer control board (PRCB)
Developing fan 11 (FM45)
Main body: Fan abnormality C-2305* Error detection signal of developing fan 12 (FM46) is detected continuously. The main body stops immediately to turn OFF the power relay (RL1). Printer control board (PRCB)
Developing fan 12 (FM46)
Main body: Erase lamp abnormality C-2401 The erase lamp /Y (ELIY) set status cannot be detected. The main body stops immediately to turn OFF the power relay (RL1). Printer control board (PRCB)
Erase lamp /Y (ELIY)
Main body: TCR sensor abnormality C-2411 The output of the TCR sensor /Y cannot be controlled. Printer control board (PRCB)
TCR sensor /Y
Main body: Developing drive abnormality C-2421 TCR sensor /Y detects a value lower than the prescribed one. Printer control board (PRCB)
Developing motor /Y (M20)
TCR sensor /Y
Main body: Developing drive abnormality C-2422 TCR sensor IM detects a value lower than the prescribed one. Printer control board (PRCB)
Developing motor IM (M21)
TCR sensor IM
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
Main body: Developing drive abnormality C-2423 While the developing motor IC (M22) is ON or after a specified period of time from the TCR sensor IC (TCRSIC) initial adjustment starts, TCRSIC detects a value lower than the prescribed one. Printer control board (PRCB)
Developing motor IC (M22)
TCR sensor IC (TCRSIC)
Main body: Developing drive abnormality C-2424 While the developing motor IK (M23) is ON or after a specified period of time from the TCR sensor IK (TCRSIK) initial adjustment starts, TCRSIK detects a value lower than the prescribed one. Printer control board (PRCB)
Developing motor IK (M23)
TCR sensor IK (TCRSIK)
Main body: TCR sensor initial adjustment abnormality (low density) C-2431 During initial adjustment of the TCR sensor /Y (TCRS/Y), TCRS/Y detects a value higher than the prescribed one with the minimum control voltage. Printer control board (PRCB)
Developing motor /Y (M20)
TCR sensor /Y (TCRSY)
Main body: TCR sensor initial adjustment abnormality (low density) C-2432 During initial adjustment of the TCR sensor IM (TCRSIM), TCRSIM detects a value higher than the prescribed one with the minimum control voltage. Printer control board (PRCB)
Developing motor IM (M21)
TCR sensor IM (TCRSIM)
Main body: TCR sensor initial adjustment abnormality (low density) C-2433 During initial adjustment of the TCR sensor IC (TCRSIC), TCRSIC detects a value higher than the prescribed one with the minimum control voltage. Printer control board (PRCB)
Developing motor IC (M22)
TCR sensor IC (TCRSIC)
Main body: TCR sensor initial adjustment abnormality (low density) C-2434 During initial adjustment of the TCR sensor IK (TCRSIK), TCRSIK detects a value higher than the prescribed one with the minimum control voltage. Printer control board (PRCB)
Developing motor IK (M23)
TCR sensor IK (TCRSIK)
Main body: TCR sensor initial adjustment abnormality (high density) C-2441 During initial adjustment of the TCR sensor /Y (TCRS/Y), TCRS/Y detects a value lower than the prescribed one with the maximum control voltage. Printer control board (PRCB)
Developing motor /Y (M20)
TCR sensor /Y (TCRSY)
Main body: TCR sensor initial adjustment abnormality (high density) C-2442 During initial adjustment of the TCR sensor IM (TCRSIM), TCRSIM detects a value lower than the prescribed one with the maximum control voltage. Printer control board (PRCB)
Developing motor IM (M21)
TCR sensor IM (TCRSIM)
Main body: TCR sensor initial adjustment abnormality (high density) C-2443 During initial adjustment of the TCR sensor IC (TCRSIC), TCRSIC detects a value lower than the prescribed one with the maximum control voltage. Printer control board (PRCB)
Developing motor IC (M22)
TCR sensor IC (TCRSIC)
Main body: TCR sensor initial adjustment abnormality (high density) C-2444 During initial adjustment of the TCR sensor IK (TCRSIK), TCRSIK detects a value lower than the prescribed one with the maximum control voltage. Printer control board (PRCB)
Developing motor IK (M23)
TCR sensor IK (TCRSIK)
Main body: Toner low density abnormality C-2451 When the developing motor /Y (M20) is ON, the difference between the maximum and minimum detection values of the TCR sensor /Y exceeds the specified value. Printer control board (PRCB)
Developing motor /Y (M20)
TCR sensor /Y
Main body: Toner low density abnormality C-2452 When the developing motor /M (M21) is ON, the difference between the maximum and minimum detection values of the TCR sensor /M exceeds the specified value. Printer control board (PRCB)
Developing motor /M (M21)
TCR sensor /M
Main body: Toner low density abnormality C-2453 When the developing motor IC (M22) is ON, the difference between the maximum and minimum detection values of the TCR sensor IC exceeds the specified value. Printer control board (PRCB)
Developing motor IC (M22)
TCR sensor IC
Main body: Toner low density abnormality C-2454 When the developing motor IK (M23) is ON, the difference between the maximum and minimum detection values of the TCR sensor IK exceeds the specified value. Printer control board (PRCB)
Developing motor IK (M23)
TCR sensor IK
Main body: Process unit mount connection abnormality C-2470 Process unit mount is not connected. Printer control board (PRCB)
Process mount
Main body: High voltage unit /1 abnormality C-2701 Error detection signal of charging corona /Y is detected while the charging corona /Y is ON. High voltage unit /1 (HV1)
Charging corona /Y
Printer control board (PRCB)
Main body: High voltage unit /1 abnormality C-2702 Error detection signal of charging corona /M is detected while the charging corona /M is ON. High voltage unit /1 (HV1)
Charging corona /M
Printer control board (PRCB)
Main body: High voltage unit /1 abnormality C-2703 Error detection signal of charging corona IC is detected while the charging corona IC is ON. High voltage unit /1 (HV1)
Charging corona IC
Printer control board (PRCB)
Main body: High voltage unit /1 abnormality C-2704 Error detection signal of charging corona /K is detected while the charging corona /K is ON. High voltage unit /1 (HV1)
Charging corona /K
Printer control board (PRCB)
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
Main body: High voltage unit /2 abnormality C-2711 An error detection signal of the 1st transfer /Y is detected while the 1st transfer /Y is ON. The signal is detected even after turning OFF/ON for a prescribed time. • High voltage unit /2 (HV2)
• 1st transfer roller /Y
• Printer control board (PRCB)
C-2712 An error detection signal of the 1st transfer /M is detected while the 1st transfer /M is ON. The signal is detected even after turning OFF/ON for a prescribed time. • High voltage unit /2 (HV2)
• 1st transfer roller /M
• Printer control board (PRCB)
C-2713 An error detection signal of the 1st transfer IC is detected while the 1st transfer IC is ON. The signal is detected even after turning OFF/ON for a prescribed time. • High voltage unit /2 (HV2)
• 1st transfer roller IC
• Printer control board (PRCB)
C-2714 An error detection signal of the 1st transfer /K is detected while the 1st transfer /K is ON. The signal is detected even after turning OFF/ON for a prescribed time. • High voltage unit /2 (HV2)
• 1st transfer roller /K
• Printer control board (PRCB)
C-2720 An error detection signal of the 2nd transfer is detected while the 2nd transfer is ON. The signal is detected even after turning OFF/ON for a prescribed time. • High voltage unit /2 (HV2)
• 2nd transfer roller
• Printer control board (PRCB)
C-2721 An error detection signal of the separation charger is detected while the separation charger is ON. The signal is detected even after turning OFF/ON for a prescribed time. • High voltage unit /2 (HV2)
• Separation charger
• Printer control board (PRCB)
Main body: Gamma correction abnormality C-2801 The output voltage of the IDC sensor (IDCS) is detected more than the specified value on the patch /Y of the developing DC maximum output. • Printer control board (PRCB)
• Developing unit /Y
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2802 The output voltage of the IDC sensor (IDCS) is detected more than the specified value on the patch /M of the developing DC maximum output. • Printer control board (PRCB)
• Developing unit /M
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2803 The output voltage of the IDC sensor (IDCS) is detected more than the specified value on the patch /C of the developing DC maximum output. • Printer control board (PRCB)
• Developing unit /C
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2804 The output voltage of the IDC sensor (IDCS) is detected more than the specified value on the patch /K of the developing DC maximum output. • Printer control board (PRCB)
• Developing unit /K
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
Main body: Gamma correction abnormality C-2811 The proper value cannot be figured out within the specified time by the correction of the patch density correction /Y. Or, the proper value of the developing DC output is 0 or lower. • Printer control board (PRCB)
• Developing unit /Y
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2812 The proper value cannot be figured out within the specified time by the correction of the patch density correction IM. Or, the proper value of the developing DC output is 0 or lower. • Printer control board (PRCB)
• Developing unit IM
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2813 The proper value cannot be figured out within the specified time by the correction of the patch density correction IC. Or, the proper value of the developing DC output is 0 or lower. • Printer control board (PRCB)
• Developing unit IC
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2814 The proper value cannot be figured out within the specified time by the correction of the patch density correction IK. Or, the proper value of the developing DC output is 0 or lower. • Printer control board (PRCB)
• Developing unit IK
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
Main body: Dot diameter correction abnormality C-2821 The output voltage of the IDC sensor (IDCS) is detected more than the specified value on the patch /Y of the MPC maximum output. • Printer control board (PRCB)
• Developing unit /Y
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2822 The output voltage of the IDC sensor (IDCS) is detected more than the specified value on the patch IM of the MPC maximum output. • Printer control board (PRCB)
• Developing unit IM
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2823 The output voltage of the IDC sensor (IDCS) is detected more than the specified value on the patch IC of the MPC maximum output. • Printer control board (PRCB)
• Developing unit IC
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2824 The output voltage of the IDC sensor (IDCS) is detected more than the specified value on the patch IK of the MPC maximum output. • Printer control board (PRCB)
• Developing unit IK
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2831 The proper value cannot be figured out within the specified time by the correction of the dot diameter correction IY. Or, the MPC proper value is 0 or lower. • Printer control board (PRCB)
• Developing unit /Y
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
• Writing unit /Y
• Printer image processing board (PRIPB)
C-2832 The proper value cannot be figured out within the specified time by the correction of the dot diameter correction IM. Or, the MPC proper value is 0 or lower. • Printer control board (PRCB)
• Developing unit IM
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
• Writing unit IM
• Printer image processing board (PRIPB)
C-2833 The proper value cannot be figured out within the specified time by the correction of the dot diameter correction IC. Or, the MPC proper value is 0 or lower. • Printer control board (PRCB)
• Developing unit IC
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
• Writing unit IC
• Printer image processing board (PRIPB)
C-2834 The proper value cannot be figured out within the specified time by the correction of the dot diameter correction IK. Or, the MPC proper value is 0 or lower. • Printer control board (PRCB)
• Developing unit IK
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
• Writing unit IK
• Printer image processing board (PRIPB)
Main body: Gamma correction abnormality C-2840 The IDC sensor (IDCS) output value is detected not within the specified range on the IDC sensor (IDCS) base correction when the rough adjustment ends. • Printer control board (PRCB)
• IDC sensor (IDCS)
• IDC shutter solenoid (SD3)
C-2841 The LED applied voltage is detected not within the specified range on the IDC sensor (IDCS) base correction. • Printer control board (PRCB)
• IDC sensor (IDCS)
Main body: Motor abnormality C-3101 An error detection signal of M29 is detected continuously for a specified period of time while the fusing motor (M29) is ON. • Conveyance drive board (CDB)
• Printer control board (PRCB)
• Fusing motor (M29)
C-3102 While the fusing release home sensor (PS16) is ON, PS16 does not turn OFF within a specified period of time after the fusing motor (M29) turns ON. While PS16 is OFF, PS16 does not turn ON within a specified period of time after M29 turns ON. • Conveyance drive board (CDB)
• Printer control board (PRCB)
• Fusing motor (M29)
• Fusing release home sensor (PS16)
C-3103 The 2nd transfer pressure release motor (M34) does not turn OFF within a specified period of time after it turns ON. • Conveyance drive board (CDB)
• 2nd transfer pressure release motor (M34)
• 2nd transfer HP sensor (PS24)
Main body: Fan abnormality C-3301* An error detection signal of FM37 is detected continuously for a specified period of time while the fusing ventilation fan (FM37) is ON. • Printer control board (PRCB)
• Fusing ventilation fan (FM37)
Classification Malfunction code Cause Resulting operation Estimated abnormal parts Faulty part isolation DIPSW Control when
C-3302* An error detection signal of FM10 is detected continuously for a specified period of time while the fusing belt ventilation fan (FM10) is ON. • Printer control board (PRCB)
• Fusing belt ventilation fan (FM10)
C-3303 An error detection signal of FM65 is detected continuously for a specified period of time while the fusing cooling fan (FM65) is ON. • Conveyance drive board (CDB)
• Fusing cooling fan (FM65)
Main body: Fan abnormality C-3304 An error detection signal of any of FM7, FM8 or FM9 is detected continuously for a specified period of time while the fusing separation fans /1 (FM7), /2 (FM8) and /3 (FM9) are ON. The main body stops immediately to turn OFF the power relay (RL1). • Printer control board (PRCB)
• Fusing separation fan /1 (FM7)
• Fusing separation fan /2 (FM8)
• Fusing separation fan /3 (FM9)
Main body: Fusing high temperature abnormality C-3501* Fusing high temperature abnormality. The temperature sensor /1 (TH1) detects 250 °C or higher value continuously for a specified period of time. The main body stops immediately to turn OFF the power relay (RL1). • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
C-3502* Fusing high temperature abnormality. The temperature sensor /3 (TH3) detects 250 °C or higher value continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /3 (TH3)
C-3503* Fusing high temperature abnormality. The temperature sensor /2 (TH2) detects 250 °C or higher value continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /2 (TH2)
C-3504* Fusing high temperature abnormality. The temperature sensor /4 (TH4) detects 250 °C or higher value continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /4 (TH4)
C-3505* Fusing high temperature abnormality. The temperature sensor /1 (TH1) detects 150 °C or higher value continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
C-3506* Fusing high temperature abnormality. The temperature sensor /2 (TH2) detects 150 °C or higher value continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /2 (TH2)
C-3508* Paper is wound around the fusing roller. J31-02 occurs 4 times in a row. • Fusing unit
• Printer control board (PRCB)
• Conveyance drive board (CDB)
• Registration motor (M30)
• High voltage unit /1 (HV1)
• High voltage unit /2 (HV2)
• Fusing paper exit sensor (PS17)
Main body: Fusing high temperature abnormality C-3509* Fusing roller /Up temperature gap abnormality. When the fusing roller /Up is higher than the specified temperature, the gap detected by the temperature sensors /1 (TH1) and /3 (TH3) are larger than the specified value. The main body stops immediately to turn OFF the power relay (RL1). • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
• Temperature sensor /3 (TH3)
Main body: Fusing low temperature abnormality C-3801* Fusing low temperature abnormality. While fusing idling or printing, the temperature sensor /1 (TH1) detects lower than the specified temperature for a specified period of time. The main body stops immediately to turn OFF the power relay (RL1). • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
• Thermostat /1 (TS1)
• Thermostat /2 (TS2)
C-3802* Fusing low temperature abnormality. While fusing idling or printing, the temperature sensor /3 (TH3) detects lower than the specified temperature for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /3 (TH3)
• Thermostat /1 (TS1)
• Thermostat /2 (TS2)
C-3803* Fusing low temperature abnormality. While fusing idling or printing, the temperature sensor /2 (TH2) detects lower than the specified temperature for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /2 (TH2)
• Thermostat /3 (TS3)
C-3804* Fusing low temperature abnormality. While fusing idling or printing, the temperature sensor /4 (TH4) detects lower than the specified temperature for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /4 (TH4)
• Thermostat /3 (TS3)
C-3805* Fusing low temperature abnormality. While fusing idling or printing, the temperature sensor /1 (TH1) detects lower than the specified temperature for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
• Thermostat /1 (TS1)
• Thermostat /2 (TS2)
C-3806* Fusing low temperature abnormality. While fusing idling or printing, the temperature sensor /2 (TH2) detects lower than the specified temperature for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /2 (TH2)
• Thermostat /3 (TS3)
Main body: Fusing sensor abnormality C-3901* Fusing high temperature abnormality (hardware detection). The temperature sensor /3 (TH3) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /3 (TH3)
C-3902* Fusing high temperature abnormality (hardware detection). The temperature sensor /4 (TH4) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /4 (TH4)
C-3903* Fusing low temperature abnormality (hardware detection). The temperature sensor /1 (TH1) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
• Thermostat /1 (TS1)
• Thermostat /2 (TS2)
C-3904* Fusing low temperature abnormality (hardware detection). The temperature sensor /3 (TH3) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /3 (TH3)
• Thermostat /1 (TS1)
• Thermostat /2 (TS2)
C-3905* Fusing low temperature abnormality (hardware detection). The temperature sensor /2 (TH2) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /2 (TH2)
• Thermostat /3 (TS3)
C-3906* Fusing low temperature abnormality (hardware detection). The temperature sensor /4 (TH4) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /4 (TH4)
• Thermostat /3 (TS3)
C-3907* Fusing high temperature abnormality (hardware detection). The temperature sensor /1 (TH1) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
C-3908* Fusing low temperature abnormality (hardware detection). The temperature sensor /1 (TH1) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
• Thermostat /1 (TS1)
• Thermostat /2 (TS2)
C-3909* Fusing high temperature abnormality (hardware detection). The temperature sensor /2 (TH2) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /2 (TH2)
Main body: Fusing sensor abnormality C-3910* Fusing low temperature abnormality (hardware detection). The temperature sensor /2 (TH2) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /2 (TH2)
• Thermostat/3 (TS3)
Main body: Fusing sensor abnormality C-3911* The detected temperature of the temperature sensor /1 (TH1) has not reached to 100°C within the specified period of time after the sub power switch (SW2) turned ON. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
• Thermostat/1 (TS1)
• Thermostat/2 (TS2)
Main body: Fusing sensor abnormality C-3912* The detected temperature of the temperature sensor /2 (TH2) has not reached to 100°C within the specified period of time after the sub power switch (SW2) turned ON. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /2 (TH2)
• Thermostat/3 (TS3)
Main body: Fusing sensor abnormality C-3913* The fusing unit is not set. • Fusing unit
• Printer control board (PRCB)
Main body: Fusing sensor abnormality C-3914* Fusing high temperature abnormality (hardware detection). The temperature sensor /1 (TH1) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
Main body: Fusing sensor abnormality C-3915* Fusing high temperature abnormality (hardware detection). The temperature sensor /2 (TH2) detects an error detection signal continuously for a specified period of time. • Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /4 (L5)
• Temperature sensor /2 (TH2)
Main body: Polygon motor abnormality C-4101 When the polygon motor /Y (M70) in the writing unit starts up or its speed changes, the lock signal of M70 is not detected within a specified period of time. • Printer control board (PRCB)
• Writing unit
Main body: Polygon motor abnormality C-4102 When the polygon motor /M (M71) in the writing unit starts up or its speed changes, the lock signal of M71 is not detected within a specified period of time. • Printer control board (PRCB)
• Writing unit
Main body: Polygon motor abnormality C-4103 When the polygon motor /C (M72) in the writing unit starts up or its speed changes, the lock signal of M72 is not detected within a specified period of time. • Printer control board (PRCB)
• Writing unit
Main body: Polygon motor abnormality C-4104 When the polygon motor /K (M73) in the writing unit starts up or its speed changes, the lock signal of M73 is not detected within a specified period of time. • Printer control board (PRCB)
• Writing unit
Main body: Polygon motor abnormality C-4111 A temperature abnormality of the polygon motor /Y (M70) in the writing unit is detected. • Printer control board (PRCB)
• Writing unit
Main body: Polygon motor abnormality C-4112 A temperature abnormality of the polygon motor /M (M71) in the writing unit is detected. • Printer control board (PRCB)
• Writing unit
Main body: Polygon motor abnormality C-4113 A temperature abnormality of the polygon motor /C (M72) in the writing unit is detected. • Printer control board (PRCB)
• Writing unit
Main body: Polygon motor abnormality C-4114 A temperature abnormality of the polygon motor /K (M73) in the writing unit is detected. • Printer control board (PRCB)
• Writing unit
Main body: Polygon motor abnormality C-4120 The temperature sensor in the writing unit /K detects the temperature abnormality. • Printer control board (PRCB)
• Writing unit
Main body: Fan abnormality C-4301 An error detection signal of any of M45 or M46 is detected continuously for a specified period of time while the developing fans /1 (FM45) and /2 (FM46) are ON. • Printer control board (PRCB)
• Developing fan /1 (FM45)
• Developing fan /2 (FM46)
Main body: Writing correction drive abnormality C-4501 The tilt correction home sensor /Y (PS70) turns OFF while the tilt correction motor /Y (M74) in the writing unit is ON. • Printer control board (PRCB)
• Writing unit
Main body: Writing correction drive abnormality C-4502 The tilt correction home sensor /M (PS71) turns OFF while the tilt correction motor /M (M75) in the writing unit is ON. • Printer control board (PRCB)
• Writing unit
Main body: Writing correction drive abnormality C-4503 The tilt correction home sensor /C (PS72) turns OFF while the tilt correction motor /C (M76) in the writing unit is ON. • Printer control board (PRCB)
• Writing unit
Main body: Writing correction drive abnormality C-4504 The tilt correction home sensor /K (PS73) turns OFF while the tilt correction motor /K (M77) in the writing unit is ON. • Printer control board (PRCB)
• Writing unit
Main body: Writing correction drive abnormality C-4511 The tilt correction motor /Y (M74) does not turn OFF within a specified period of time after it turns ON, or the installation position of the tilt correction home sensor /Y (PS70) is improper. • Printer control board (PRCB)
• Tilt correction motor /Y (M74)
• Skew correction home sensor /Y (PS70)
Main body: Writing correction drive abnormality C-4512 The tilt correction motor /M (M75) does not turn OFF within a specified period of time after it turns ON, or the installation position of the tilt correction home sensor /M (PS71) is improper. • Printer control board (PRCB)
• Tilt correction motor /M (M75)
• Skew correction home sensor /M (PS71)
Main body: Writing correction drive abnormality C-4513 The tilt correction motor /C (M76) does not turn OFF within a specified period of time after it turns ON, or the installation position of the tilt correction home sensor /C (PS72) is improper. • Printer control board (PRCB)
• Tilt correction motor /C (M76)
• Tilt correction home sensor /C (PS72)
Main body: Writing correction drive abnormality C-4514 The tilt correction motor /K (M77) does not turn OFF within a specified period of time after it turns ON, or the installation position of the tilt correction home sensor /K (PS73) is improper. • Printer control board (PRCB)
• Tilt correction motor /K (M77)
• Tilt correction home sensor /K (PS73)
Main body: Color registration abnormality C-4520 The color registration correction has terminated abnormally. • Printer control board (PRCB)
• Color registration sensor /Fr (PS8)
• Color registration sensor /Rr (PS9)
Main body: Color registration abnormality C-4521 The color registration base line correction /Fr has terminated abnormally. • Printer control board (PRCB)
• Color registration sensor /Fr (PS8)
• Color registration shutter solenoid (SD2)
Main body: Color registration abnormality C-4522 The color registration base line correction /Rr has terminated abnormally. • Printer control board (PRCB)
• Color registration sensor /Rr (PS9)
• Color registration shutter solenoid (SD2)
Main body: Beam interval correction abnormality C-4545 The beam interval correction (Y) has terminated abnormally. The main body stops immediately to turn OFF the power relay (RL1). • Writing unit
Main body: Beam interval correction abnormality C-4546 The beam interval correction (M) has terminated abnormally. • Writing unit
Main body: Beam interval correction abnormality C-4547 The beam interval correction (C) has terminated abnormally. • Writing unit
Main body: Beam interval correction abnormality C-4548 The beam interval correction (K) has terminated abnormally. • Writing unit
Main body: Color registration board /Fr (Y) data undetected abnormality C-4601 The color registration board /Fr (CRB/Fr) has not detected any data of Y toner. • Printer control board
• Color registration sensor /Fr (PS8)
• Color registration board /Fr (CRB/Fr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Fr (M) data undetected abnormality C-4602 The color registration board /Fr (CRB/Fr) has not detected any data of M toner. The main body stops immediately to turn OFF the power relay (RL1). • Printer control board
• Color registration sensor /Fr (PS8)
• Color registration board /Fr (CRB/Fr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Fr (C) data undetected abnormality C-4603 The color registration board /Fr (CRB/Fr) has not detected any data of C toner. • Printer control board
• Color registration sensor /Fr (PS8)
• Color registration board /Fr (CRB/Fr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Fr (K) data undetected abnormality C-4604 The color registration board /Fr (CRB/Fr) has not detected any data of K toner. • Printer control board
• Color registration sensor /Fr (PS8)
• Color registration board /Fr (CRB/Fr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Rr (Y) data undetected abnormality C-4621 The color registration board /Rr (CRB/Rr) has not detected any data of Y toner. The main body stops immediately to turn OFF the main relay (RL1). • Printer control board
• Color registration sensor /Rr (PS9)
• Color registration board /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Rr (M) data undetected abnormality C-4622 The color registration board /Rr (CRB/Rr) has not detected any data of M toner. The main body stops immediately to turn OFF the power relay (RL1). • Printer control board
• Color registration sensor /Rr (PS9)
• Color registration board /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Rr (C) data undetected abnormality C-4623 The color registration board /Rr (CRB/Rr) has not detected any data of C toner. • Printer control board
• Color registration sensor /Rr (PS9)
• Color registration board /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Rr (K) data undetected abnormality C-4624 The color registration board /Rr (CRB/Rr) has not detected any data of K toner. • Printer control board
• Color registration sensor /Rr (PS9)
• Color registration board /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Fr (Y) abnormality C-4631 The histogram processing of Y toner has terminated abnormally on the color registration board /Fr (CRB/Fr). • Printer control board
• Color registration sensor /Fr (PS8)
• Color registration board /Fr (CRB/Fr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Fr (M) abnormality C-4632 The histogram processing of M toner has terminated abnormally on the color registration board /Fr (CRB/Fr). • Printer control board
• Color registration sensor /Fr (PS8)
• Color registration board /Fr (CRB/Fr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Fr (C) abnormality C-4633 The histogram processing of C toner has terminated abnormally on the color registration board /Fr (CRB/Fr). • Printer control board
• Color registration sensor /Fr (PS8)
• Color registration board /Fr (CRB/Fr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Fr (K) abnormality C-4634 The histogram processing of K toner has terminated abnormally on the color registration board /Fr (CRB/Fr). • Printer control board
• Color registration sensor /Fr (PS8)
• Color registration board /Fr (CRB/Fr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Rr (Y) abnormality C-4651 The histogram processing of Y toner has terminated abnormally on the color registration board /Rr (CRB/Rr). • Printer control board
• Color registration sensor /Rr (PS9)
• Color registration board /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Rr (M) abnormality C-4652 The histogram processing of M toner has terminated abnormally on the color registration board /Rr (CRB/Rr). • Printer control board
• Color registration sensor /Rr (PS9)
• Color registration board /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Rr (C) abnormality C-4653 The histogram processing of C toner has terminated abnormally on the color registration board /Rr (CRB/Rr). • Printer control board
• Color registration sensor /Rr (PS9)
• Color registration board /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration board /Rr (K) abnormality C-4654 The histogram processing of K toner has terminated abnormally on the color registration board /Rr (CRB/Rr). • Printer control board
• Color registration sensor /Rr (PS9)
• Color registration board /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration correction abnormality (Y) C-4661 The color registration correction /Y has terminated abnormally. • Printer control board
• Color registration sensor /Fr (PS8), /Rr (PS9)
• Color registration board /Fr (CRB/Fr), /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration correction abnormality (M) C-4662 The color registration correction /M has terminated abnormally. • Printer control board
• Color registration sensor /Fr (PS8), /Rr (PS9)
• Color registration board /Fr (CRB/Fr), /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Color registration correction abnormality (C) C-4663 The color registration correction /C has terminated abnormally. • Printer control board
• Color registration sensor /Fr (PS8), /Rr (PS9)
• Color registration board /Fr (CRB/Fr), /Rr (CRB/Rr)
• Color registration shutter solenoid (SD2)
Main body: Image processing abnormality C-4701 FIFO address abnormality for the printer. While in the image write, the expansion processing of image data that is read in does not terminate correctly. The main body stops immediately to turn OFF the power relay (RL1). • Printer control board (PRCB)
• Overall control board (OACB)
• Memory control board /1 (MCB1)
Main body: Image processing abnormality C-4702 An error interrupt occurs with the compression/expansion chip FIFO. • Overall control board (OACB)
• Memory control board /1 (MCB1)
Main body: Image processing abnormality C-4703 Image data expansion abnormality. • Overall control board (OACB)
• Memory control board /1 (MCB1)
Main body: Image processing abnormality C-4705 While in the image write, the expansion processing from the memory to the printer does not terminate within a specified period of time. The output from the page memory to the printer does not terminate within a specified period of time. The PVV is not detected within a specified period of time. • Printer control board (PRCB)
• Printer image processing board (PRIPB)
• Memory control board /1 (MCB1)
• Overall control board (OACB)
Main body: Image processing abnormality C-4706 While in the image write, despite of no resource provided, an inappropriate processing such as accessing to the elongation device is made. • Overall control board (OACB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing abnormality C-4708 When accessing to the memory device, a defective software is detected. • Overall control board (OACB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing abnormality C-4709 The expansion processing from the memory to the page memory does not terminate within a specified period of time. The compression processing from the page memory to the memory does not terminate within a specified period of time. The development from the memory to the page memory does not terminate within a specified period of time. The transmission of the compressed data from memory to memory does not terminated within a specified period of time. • Overall control board (OACB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing abnormality C-4713 A page memory for printing cannot be secured. • Printer image processing board (PRIPB)
• Memory control board /1 (MCB1)
• Overall control board (OACB)
Main body: Image processing abnormality N C-4714 When executing APC, the Index sensor output does not change. The index sensor failed to detect the laser because the polygon mirror does not rotate, the position of the index sensor is improper, or the index sensor is defective. • Printer image processing board (PRIPB)
• Writing unit N
Main body: Image processing abnormality /M C-4715 When executing APC, the Index sensor output does not change. The index sensor failed to detect the laser because the polygon mirror does not rotate, the position of the index sensor is improper, or the index sensor is defective. • Printer image processing board (PRIPB)
• Writing unit /M
Main body: Image processing abnormality IC C-4716 When executing APC, the Index sensor output does not change. The index sensor failed to detect the laser because the polygon mirror does not rotate, the position of the index sensor is improper, or the index sensor is defective. • Printer image processing board (PRIPB)
• Writing unit IC
Main body: Image processing abnormality IK C-4717 When executing APC, the Index sensor output does not change. The index sensor failed to detect the laser because the polygon mirror does not rotate, the position of the index sensor is improper, or the index sensor is defective. • Printer image processing board (PRIPB)
• Writing unit /K
Main body: Image processing abnormality /Y C-4718 APC abnormality. The laser does not turn ON because 12V DC power source for driving laser is not fed, MPC is wrong, or the laser is defective. • Printer image processing board (PRIPB)
• Writing unit /Y
Main body: Image processing abnormality IM C-4719 APC abnormality. The laser does not turn ON because 12V DC power source for driving laser is not fed, MPC is wrong, or the laser is defective. • Printer image processing board (PRIPB)
• Writing unit IM
Main body: Image processing abnormality IC C-4720 APC abnormality. The laser does not turn ON because 12V DC power source for driving laser is not fed, MPC is wrong, or the laser is defective. • Printer image processing board (PRIPB)
• Writing unit IC
Main body: Image processing abnormality IK C-4721 APC abnormality. The laser does not turn ON because 12V DC power source for driving laser is not fed, MPC is wrong, or the laser is defective. • Printer image processing board (PRIPB)
• Writing unit /K
Main body: Image processing abnormality /Y C-4722 Connection abnormality between the index board I Y (IDB/Y) or the laser drive board /Y (LDB/Y) and the printer image processing board (PRIPB). • Printer image processing board (PRIPB)
• Writing unit /Y
Main body: Image processing abnormality IM C-4723 Connection abnormality between the index board I M (IDBIM) or the laser drive board IM (LDBIM) and the printer image processing board (PRIPB). • Printer image processing board (PRIPB)
• Writing unit IM
Main body: Image processing abnormality IC C-4724 Connection abnormality between the index board I C (IDBIC) or the laser drive board IC (LDBIC) and the printer image processing board (PRIPB). • Printer image processing board (PRIPB)
• Writing unit IC
Main body: Image processing abnormality IK C-4725 Connection abnormality between the index board I K (IDBIK) or the laser drive board IK (LDBIK) and the printer image processing board (PRIPB). • Printer image processing board (PRIPB)
• Writing unit /K
Main body: Image processing abnormality C-4840 The engine section has kept driving continuously for a specified period of time without producing image or process patch. • Printer control board (PRCB)
• Printer control program
Main body: Image processing abnormality C-4850* The overall control software accesses an illegal address. • Overall control board (OACB)
Main body: Communication error C-5001 12V DC abnormality. An error signal is detected continuously for a specified period of time. • DC power supply /1 (DCPS1)
• Printer control board (PRCB)
Main body: Communication error C-5002 24V DC abnormality. An error signal is detected continuously for a specified period of time after REN/2 turns ON. • Printer control board (PRCB)
• DC power supply /2 (DCPS2)
• Each loading of PRCB connection (motor, solenoid and clutch)
Main body: Communication error C-5003 Conveyance drive board (CDB) 24VDC abnormality. An error signal of 24VDC for CDB is detected. • DC power supply /2 (DCPS2)
• Conveyance drive board (CDB)
Main body: Communication error C-5004 Laser correction motor 5VDC abnormality. An abnormality of 5VDC for the tilt correction motors /Y (M74), /M (M75), IC (M76), /K (M77) • DC power supply /1 (DCPS1)
Main body: Communication error C-5005 Conveyance drive board (CDB) 12VDC abnormality. • Printer control board (PRCB)
• Conveyance drive board (CDB)
Main body: Communication error C-5010 A line status error or a checksum error occured between the overall control board (OACB) and the printer control board (PRIPB) and it cannot be recovered by sending a retransmission request. Recovery failed even after retransmission. A sufficient space cannot be obtained in the circular buffer within a specified period of time. • Printer control board (PRCB)
• Overall control board (OACB)
Main body: Fan abnormality C-5301 An error detection signal of FM1 is detected continuously for a specified period of time while the power supply cooling fan /1 (FM1) is ON. • Overall control board (OACB)
• Power supply cooling fan /1 (FM1)
Main body: Fan abnormality C-5302 An error detection signal of FM5 is detected continuously for a specified period of time while the image processing cooling fan /1 (FM5) is ON. • Overall control board (OACB)
• Image processing cooling fan /1 (FM5)
Main body: Fan abnormality C-5303 An error detection signal of FM6 is detected continuously for a specified period of time while the image processing cooling fan /2 (FM6) is ON. • Overall control board (OACB)
• Image processing cooling fan /2 (FM6)
Main body: HDD unit cooling fan abnormality C-5304 An error detection signal of FM81 or FM82 is detected continuously for a specified period of time while the HDD unit cooling fans /1 (FM81) and /2 (FM82) are ON. An error detection signal is detected continuously while retrying power feed several times. The main body stops immediately to turn OFF the main relay (RL1). • HDD unit cooling fan /1 (FM81)
• HDD unit cooling fan /2 (FM82)
Main body: Fan abnormality C-5305 An error detection signal of FM3 or FM4 is detected continuously for a specified period of time while the power supply cooling fans /3 (FM3) and /4 (FM4) are ON. The main body stops immediately to turn OFF the power relay (RL1). • Printer control board (PRCB)
• Power supply cooling fan /3 (FM3)
• Power supply cooling fan /4 (FM4)
Main body: Scanner abnormality C-6101 While in the home position search operation, the scanner home sensor (PS1) does not turn ON within a specified period of time after the scanner motor (M1) turns ON. The main body stops immediately to turn OFF the power relay (RL1). • Printer control board (PRCB)
• Scanner drive board (SCDB)
• Scanner motor (M1)
• Scanner home sensor (PS1)
Main body: Scanner abnormality C-6102 When in optics scan returning operation, the scanner home sensor (PS1) does not turn ON within a specified period of time after the scanner motor (M1) turns ON. • Printer control board (PRCB)
• Scanner drive board (SCDB)
• Scanner motor (M1)
• Scanner home sensor (PS1)
Main body: Fan abnormality C-6301 An error detection signal of FM2 is detected continuously for a specified period of time while the scanner cooling fan (FM2) is ON. • Printer control board (PRCB)
• Scanner drive board (SCDB)
• Scanner cooling fan (FM2)
Main body: Image processing C-6701 When processing images, a filter coefficient cannot be created normally. • Scanner image processing board (SCIPB)
Main body: Image processing C-6702 Address error of the scanner FIFO. While in the image read, the compression processing of image data that is read in does not terminate correctly. • Overall control board (OACB)
• Memory control board /1 (MCB1)
Main body: Image processing C-6703 After negation of SW, the compression of images that are read in and their development into the page memory are not terminated within a specified period of time. • Scanner image processing board (SCIPB)
• Memory control board /1 (MCB1)
• Overall control board (OACB)
• Printer control board (PRCB)
Main body: Image processing C-6704 While in the image read, the compression processing from the scanner into the memory does not terminate within a specified period of time. The development from the scanner into the page memory does not terminate within a specified period of time. The SVV is not detected within a specified period of time. • Scanner image processing board (SCIPB)
• Memory control board /1 (MCB1)
• Overall control board (OACB)
• Printer control board (PRCB)
Main body: Image processing C-6705 While in the image read, despite of no resource provided, an inappropriate processing such as accessing to the compression device is made. • Scanner image processing board (SCIPB)
• Memory control board /1 (MCB1)
Main body: Image processing C-6706 While in the image read, SVV does not turn OFF within a specified period of time and the preparation for scanning the next page cannot be started. • Scanner image processing board (SCIPB)
• Memory control board /1 (MCB1)
• Overall control board (OACB)
• Printer control board (PRCB)
Main body: Image processing C-6707 Shading correction abnormality (GA abnormality). • Scanner image processing board (SCIPB)
Main body: Image processing C-6708 AOC/AGC adjustment abnormality.
The light blocking cover and the lens cover of the scanner section are removed.
The connector of the CCD board (CCDB) is not disconnected.
The power cable of CCDB is disconnected.
The IC protector of the CCD board (CCDB) is removed.
Overexposure of the exposure lamp (L1). L1 does not light.
• CCD board (CCDB)
• Scanner image processing board (SCIPB)
• CCD lens unit
• Scanner drive board (SCDB)
• Exposure lamp (L1)
• Scanner inverter board (S_INVB)
Main body: Image processing C-6709 The adjustment data evacuated by resolutions is not available. • Scanner image processing board (SCIPB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing C-6710 A density conversion gamma curve cannot be created normally. • Scanner image processing board (SCIPB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing C-6711 Pulse width modulation IC calibration cannot be started normally. • Scanner image processing board (SCIPB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing C-6712 Pulse width modulation IC calibration cannot be completed normally. • Scanner image processing board (SCIPB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing C-6713 APC initial sampling is started before MPC is completed. • Printer image processing board (PRIPB)
• Writing unit
Main body: Image processing C-6714 MPC is started before APC is in progress. • Printer image processing board (PRIPB)
• Writing unit
Main body: Image processing C-6715 Sub scan beam correction is started before APC or MPC is completed. • Printer image processing board (PRIPB)
• Program of printer control board (PRCB)
Main body: Image processing C-6716 Sub scan beam interval correction is started with write clock abnormality occurred due to noncompletion of AD9561 initialization. • Printer image processing board (PRIPB)
• Program of printer control board (PRCB)
Main body: Image processing C-6717 N-in-1 page area abnormality. Due to an image area abnormality of the memory, images cannot be expanded on the memory. • Printer image processing board (PRIPB)
• Program of printer control board (PRCB)
Main body: Image processing C-6720 The scan operation starts before the centering adjustment is terminated. • Software bug
Main body: Image processing C-6721 The AGC is retried due to the decreased light volume of the exposure lamp (L1). However, no error occurs. • CCD board (CCDB)
• Scanner image processing board (SCIPB)
• CCD lens unit
• Scanner drive board (SCDB)
• Exposure lamp (L1)
Main body: Image processing C-6722 A PWM gamma curve is not created properly. • Printer image processing board (PRIPB)
• Writing unit
Main body: Image processing C-6723 Connection abnormality between the CCD board (CCDB) and the image processing board (IPB). • Scanner image processing board (SCIPB)
• CCD board (CCDB)
• CCD lens unit
• Exposure lamp (L1)
• Scanner drive board (SCDB)
Main body: Image processing C-6724 When the sub power switch (SW2) turns ON, connection check of reading system board failed. • Scanner image processing board (SCIPB)
• CCD board (CCDB)
• CCD lens unit
• Exposure lamp (L1)
• Scanner drive board (SCDB)
Main body: Image processing C-6725 The parameter setting cannot be performed while preparing for scanning. • Scanner image processing board (SCIPB)
Main body: Communication error C-6801 After the sub power switch (SW2) turns ON, the communication between the overall control board (OACB) and the operation board /1 (081) is not started within a specified period of time. • Overall control board (OACB)
• Operation board /1 (081)
Main body: Communication error C-7001 Communication error. The main body and the post processing machine stop immediately to turn OFF the power relay (RL1). • Printer control board (PRCB)
DF: DF communication error C-8001 Communication error between the main body and DF. The main body stops immediately to turn OFF the power relay (RL1). • Printer control board (PRCB)
• DF control board (DFCB)
DF: Paper feed motor error C-8101 Paper feed motor (M301) error The main body stops immediately to turn OFF the main relay (RL1). • Paper feed motor (M301)
• DF control board (DFCB)
DF: Conveyance motor error C-8102 Conveyance motor (M302) error • Conveyance motor (M302)
• DF control board (DFCB)
DF: Reverse / paper exit motor error C-8103 Reverse / paper exit motor (M303) error • Reverse / paper exit motor (M303)
• DF control board (DFCB)
DF: Registration sensor error C-8401 Registration sensor (PS301) error • Original registration sensor (PS301)
• DF control board (DFCB)
DF: Timing sensor error C-8402 Timing sensor (PS302) error • Timing sensor (PS302)
• DF control board (DFCB)
DF: Reverse sensor error C-8403 Reverse sensor (PS305) error • Reverse sensor (PS305)
• DF control board (DFCB)
DF: Paper exit sensor error C-8404 Paper exit sensor (PS306) error • Paper exit sensor (PS306)
• DF control board (DFCB)
DF: Size VR error C-8405 Size VR (VR301) error • Size VR (VR301)
• DF control board (DFCB)
DF: Non-volatile memory error C-8406 Non-volatile memory error • DF control board (DFCB)
DF: DF abnormality C-8407 When the sub power switch (SW2) is ON, it is detected that the control program of the DF control board (DFCB) is unwritten. • DF control board (DFCB)
Main body: Communication error C-C101 When the sub power switch (SW2) turns ON, a response from the printer control board (PRCB) has not received within a specified period of time. The main body stops immediately to turn OFF the power relay (RL1). • Printer control board (PRCB)
• Overall control board (OACB)
Main body: Communication error C-C102 Communication error of the printer control board (PRCB) • Printer control board (PRCB)
Main body: Communication error C-C103 Communication error of the control panel • Operation board /1 (081)
• Printer image processing board (PRIPB)
• Scanner image processing board (SCIPB)
• Memory control board /1 (MCB)
• Printer control board (PRCB)
• Overall control board (OACB)
• Sub power switch (SW2)
Main body: ISW abnormality C-C104 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the printer control program. • Printer control firmware
Main body: ISW abnormality C-C106 No normal header is transmitted within a specified period of time after ISW is started. • Relay board /U (RBU)
• USB memory
Main body: ISW abnormality C-C107 While in data transmission by ISW, a checksum error or a header error is detected in the downloaded data. • Relay board /U (RBU)
• USB memory
• Program file abnormality
Main body: ISW abnormality C-C108 While in data transmission by ISW, data cannot be written in the flash ROM properly. • Relay board /U (RBU)
• USB cables
• Board to which the program is transferred
FS: FS ISW unwritten C-C109 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the FS firmware. The main body stops immediately to turn OFF the main relay (RL1). • FNSCB firmware
• FNS control board (FNSCB)
LS: LS ISW unwritten C-C111 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (1st tandem). • LSCB firmware
• LS control board (LSCB)
LS: LS ISW unwritten C-C112 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (2nd tandem). • LSCB firmware
• LS control board (LSCB)
FD: FD ISW unwritten C-C113 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the FD firmware. • FDCB firmware
• FD control board (FDCB)
SD: SD ISW unwritten C-C114 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the SD firmware. • SDCB firmware
• SD control board (SDCB)
PB: PB ISW unwritten C-C116 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the PB firmware. • PB firmware
• PB control board (PBCB)
GP: GP ISW unwritten C-C117 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the GP firmware. • GP firmware
• Punch Controller PCB
RU: RU-506 ISW unwritten C-C118 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the RU firmware. • RU-506 firmware
• RU control board (RUCB)
RU: RU-509 ISW unwritten C-C119 When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the RU program. • RU firmware
• RU control board (RUCB)
Main body: ISW abnormality C-C120 Printer control board (PRCB) firmware abnormality The main body stops immediately to turn OFF the power relay (RL1). • Printer control firmware
Main body: HDD initialization abnormality C-D0E0 There is HDD to be initialized. The main body stops immediately to turn OFF the main relay (RL1). • HDD/Y (HDD/Y)
• HDD/M (HDD/M)
• HDD/C (HDD/C)
• HDD/K (HDD/K)
• HDD/A (HDD/A)
• HDD/P (HDD/P)
DIPSW18-7 HDD unusable (HDD not connected). However, it cannot be detached when IC-601 is connected.
Main body: HDD abnormality (any of Y, M, C, K or A) C-D0E1 HDD (Y/M/C/K/A) is not connected. Or damaged, or while in initialization. • HDD/Y (HDD/Y)
• HDD/M (HDD/M)
• HDD/C (HDD/C)
• HDD/K (HDD/K)
• HDD/A (HDD/A)
• Memory control board /1 (MCB1)
DIPSW18-7 HDD unusable (HDD not connected). However, it cannot be detached when IC-601 is connected.
Main body: HDD/P abnormality C-D0E2 HDD/P unconnected or damaged, or while in initialization. • HDD/P (HDD/P)
• Memory control board /P (MCB/P)
DIPSW18-7 HDD unusable (HDD not connected). However, it cannot be detached when IC-601 is connected.
Main body: HDD/Y read / write abnormality C-D0E3 Writing/reading to the HDD/Y failed. • HDD/Y (HDD/Y) DIPSW18-7 HDD unusable (HDD not connected). However, it cannot be detached when IC-601 is connected.
Main body: HDD/M read / write abnormality C-D0E4 Writing/reading to the HDD/M failed. • HDD/M (HDD/M) DIPSW18-7 HDD unusable (HDD not connected). However, it cannot be detached when IC-601 is connected.
Main body: HDD/C read / write abnormality C-D0E5 Writing/reading to the HDD/C failed. • HDD/C (HDD/C) DIPSW18-7 HDD unusable (HDD not connected). However, it cannot be detached when IC-601 is connected.
Main body: HDD/K read / write abnormality C-D0E6 Writing/reading to the HDD/K failed. • HDD/K (HDD/K) DIPSW18-7 HDD unusable (HDD not connected). However, it cannot be detached when IC-601 is connected.
Main body: HDD/A read / write abnormality C-D0E7 Writing/reading to the HDD/A failed. • HDD/A (HDD/A) DIPSW18-7 HDD unusable (HDD not connected). However, it cannot be detached when IC-601 is connected.
Main body: HDD/P read / write abnormality C-D0E8 Writing/reading to the HDD/P failed. • HDD/P (HDD/P)
• Memory control board /P (MCB/P)
DIPSW18-7 HDD unusable (HDD not connected). However, it cannot be detached when IC-601 is connected.
Main body: HDD verify abnormality C-D0EF An error is detected while in HDD verify check.
* SC is not counted.
• HDD/Y (HDD/Y)
• HDD/M (HDD/M)
• HDD/C (HDD/C)
• HDD/K (HDD/K)
• HDD/A (HDD/A)
• HDD/P (HDD/P)
• Memory control board /1 (MCB1)
• Memory control board /P (MCB/P)
• Overall control board (OACB)
Main body: HDD Lock abnormality C-D0F0 HDD Lock abnormality while in enhanced security. HDD is locked due to incorrect password, password unset or security OFF. • HDD/Y (HDD/Y)
• HDD/M (HDD/M)
• HDD/C (HDD/C)
• HDD/K (HDD/K)
• HDD/A (HDD/A)
• HDD/P (HDD/P)
Main body: Security abnormality C-DC## Security abnormality Contact to Konica Minolta before carrying on the action.
Main body: Image processing abnormality C-E001 The message queue is insufficient or destroyed. The main body stops immediately to turn OFF the power relay (RL1). • Scanner image processing board (SCIPB)
• Printer image processing board (PRIPB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing abnormality C-E002 The parameter value is in excess of the permissible limits. • Scanner image processing board (SCIPB)
• Printer image processing board (PRIPB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing abnormality C-E003 The ID of the task that sends the message queue is undefined. • Scanner image processing board (SCIPB)
• Printer image processing board (PRIPB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
Main body: Image processing abnormality C-E004 The receiving event of the message is undefined. • Scanner image processing board (SCIPB)
• Printer image processing board (PRIPB)
• Memory control board /1 (MCB1)
• Program of overall control board (OACB)
C-E005 Memory access abnormality. • Scanner image processing board (SCIPB)
• Printer image processing board (PRIPB)
• Memory control board /1 (MCB1)
• Overall control board (OACB)
C-E006 Header address read out abnormality. • Scanner image processing board (SCIPB)
• Printer image processing board (PRIPB)
• Memory control board /1 (MCB1)
• Overall control board (OACB)
C-E007 Header address read out abnormality. • Printer image processing board (PRIPB)
• Memory control board /1 (MCB1)
• Overall control board (OACB)
Main body: Output paper density automatic adjustment abnormality C-E008 An error is detected while in the output paper density adjustment. The main body stops immediately to turn OFF the main relay (RL1). • Color density sensor unit
Main body: Printer control non-volatile initial value abnormality C-E009 Wrong initial value is detected in the printer control area. The main body stops immediately to turn OFF the main relay (RL1). • PRCB firmware
• Printer control board (PRCB)